Heta Ambition 5 Скачать руководство пользователя страница 10

10 

If the wood is damp and inadequately seasoned, 
a large proportion of the energy in the fuel will be 
used to vaporize the water and this will all disap-
pear up the chimney. Thus, it is important to use 
dry,  well  seasoned  wood,  for  eg.  wood  with  a 
moisture content of less than 20 %. Achieve this 
by storing the wood for 1–2 years before use.
Pieces of firewood with a diameter of more than
10 cm should be split before before storing. The
pieces of firewood should be of an appropriate
length (approx. 35-40 cm) so that they can lie
flat on the bed of embers.
If you store your wood outdoors, it is best to 
cover it.

examples of fuel values

for  different  woods  and  their  typical  densities 
per cubic meter, specified for 100% wood with 
a moisture content of 18%.

Wood

kg/m

3

Wood

kg/m

3

Beech

710

Willow

560

Oak

700

Alder

540

Ash

700

Scotch pine

520

Elm

690

Larch

520

Maple

660

Lime

510

Birch

620

Spruce

450

Mountain pine

600

Poplar

450

It is advised not to use oil-containing woods 
like teak tree and mahogany, as this can cau-
se damage to the glass.

heating value in wood

You have to use about 2.4 kg normal wood to 
replace one litre of heating oil. All woods have 
almost the same heating value per kg, which is 
about 5.27 kW/hour for absolute dry wood.
Wood with a moistness of 18% has a efficiency
of about 4.18 kW / hour per kg, and one litre 
heating oil contains about 10 kW / hour.

Co

2

 release

At combustion 1000 litres of heating oil forms 3.171 
tons  CO

2

.  As  wood  is  a  CO

2

  neutral  heat/energy 

source, you save the environment about 1.3 kg CO

2

 

every time you have used 1 kg normal wood.

1.11 operational problems

The  chimney  must  be  swept  at  least  once  a 
year, we recommend the use of a NACS (natio-

nal  association  of  chimney  sweeps)  registered 
chimney sweep.

In the event of smoke or malodorous fumes are
being  produced,  you  must  first  check  to  see 
whether the chimney is blocked.

The chimney must, of course, always provide the 
minimum draft necessary to ensure that it is pos-
sible to regulate the fire. Please note, how-ever, 
that chimney draft is dependent on the weather 
conditions. In high winds, the draft can become 
so  powerful  that  it  may  be  necessary  to  fit  a 
damper in the flue gas pipe to regulate the draft.

When  cleaning  the  chimney,  soot  and  other 
deposits  may  come  to  fall  on  the  baffle  plate, 
remove and clean it. In cases where the wood 
burns too quickly, this may be due to excessive 
chimney draft. You should also check to make 
sure that the door seal and ash pan seal is intact 
and correctly fitting. 

If the stove it generating too little heat, this may
be because you are firing with wet wood. In this
case, much of the heating energy is used to dry
the  wood,  resulting  in  poor  efficiency,  poten-
tially damaging the vermiculite and an increased 
risk of soot deposits in the chimney.

1.12 Chimney fire

In case of a chimney fire, which often results from 
incorrect  operation/maintenance  or  prolonged 
use  of  damp  wood,  close  the  door  and  the  air 
supply completely, to help slow/smother the fire.

Call the fire department. The stove and chimi-
ney must be inspected before use again.

1.13 Maintenance

The surface of the stove is treated with a heat-
resistant  paint.  The  stove  should  be  cleaned 
with a damp cloth.
Any damage to the surface in the form of chips 
or  scratches  can  be  repaired  using  touch-up 
paint, which is available in spray cans.

1.14 Cleaning the glass

Incorrect firing, for example using wet wood, 
can result in the viewing window becoming 
covered in soot. This soot can be easily and 
effectively removed by using proprietary stove 
glass cleaner.

Содержание Ambition 5

Страница 1: ...1 oPeratinG anD installation instrUCtions Danish design Danish Quality Danish Production www heta dk EN AMBITION Stove is exemt for use in smoke control areas when burning dry wood Pending...

Страница 2: ...883 62 mgC Nm3 ved 13 O2 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combustible materials Rear whit insulation whitout insulation S...

Страница 3: ...883 92 mgC Nm3 ved 13 O2 Fire safety Reaction to fire A1 Test of fire safety in connection with the burning of wood Approved Distance to combustible materials Rear whit insulation whitout insulation S...

Страница 4: ...imum fuel economy The Ambitions are recommended as exempt for use within smoke control areas SCA throughout the UK see clean air act Appendix A of the air supply regulation so that it can t be closed...

Страница 5: ...dealers Neverthe less when in transport or handling damage of the often heavy stoves can occur It is important that upon receipt check your Heta product completely and report any damage or defects to...

Страница 6: ...art materiale bag ovn Afstand l br ndbart materiale side af ovn Afstand l m bel Middel CO emission nominel last ved 13 O2 Middel CO emission I Mg Nm3 ved 13 O2 656 Mg R ggas Temp Nominel last 261 C St...

Страница 7: ...n 5 and 42 for Ambition 8 of its fully open position A permanent amount of air will therefore enter the firebox to feed the fire producing negligible amounts of smoke and unburnt hydrocarbons The appl...

Страница 8: ...eft for a long time Never empty ash into a combustible container 1 7 Reduced burning The stove is approved for intermittent use Never turn down the air down so much that there does not come any flames...

Страница 9: ...create lower flue tempe ratures Wind and weather conditions also in fluence draft in some cases it may be disad vantageous wind direction combined with the position of the chimney can cause negative d...

Страница 10: ...NACS natio nal association of chimney sweeps registered chimney sweep In the event of smoke or malodorous fumes are being produced you must first check to see whether the chimney is blocked The chimne...

Страница 11: ...on chamber is visible Too rapid combustion Too much chimney draft To test you can open the cleaning hatch but remember to close it again Measure the chimney draft and install a damper in the flue pipe...

Страница 12: ...C VI C Cleaning combustion air intake C C Cleaning of the firebox C VI C Checking switch gasket for door C S VI C S Checking changing gasket for glass C S VI C S Checking changing gasket for flue pipe...

Страница 13: ...17 Cleaning after sweeping or before replacing vermiculite stones Note it may be necessary to clean vaccum the holes and air ducts behind the rear stone Order of removing Fire bricks Replace in revers...

Страница 14: ...08 9086 Hinge pin 6x40 SS 2 6 0016 0031 Handle 1 7 1013 0732 Door hock 1 8 0008 1007 Flat screw M6x6 4 9 0008 0040 M5x10 Ch 2 10 0008 9015 Pin 5x26 1 11 0008 3503 Brass disc M6 6 4 11 1 6 1 12 1013 07...

Страница 15: ...2 Back stone top right 1 8 0023 004879 Back stone bottom right 1 Ambition 5 Parts Inside fire chamber Ambition 8 Parts Inside fire chamber 6 5 2 1 3 7 8 4 Pos No Name Qty 1 0023 005003 Back stone top...

Страница 16: ...tallation Instructions Contents 2 Installation instructions 17 2 1 Distance requirements 17 2 2 Floor 17 2 3 Chimney connection 17 2 4 Combustion air and ventilation 18 2 5 Stovedrawings measurments 1...

Страница 17: ...ront of the fireplace stove the substrate must consist of non combustible material for ex Steel glass plate stone or tile floor The size of the non combustible surface must follow the applicable natio...

Страница 18: ...ir inlet vent The air inlet vent must be fitted correctly and insulated to prevent formation of condensate The cross section of the vent and grille must be at least 78 cm If the vent leads out into th...

Страница 19: ...19 345 100 125 137 345 920 381 920 550 458 817 Ambition 5 Ambition 8 416 100 125 mm 138 454 416 619 619 550 516 156...

Страница 20: ...nnecting direct air behind When installing external air supply connect the air intake to the direct air pipe using flexi pipe Flexi pipe not included Ambition 8 416 457 817 550 920 125 135 454 416 920...

Страница 21: ...mensions in mm Distance to flamable materials A rear the stove with insulation without insulation B at the sides C over the stove D to furniture Ambition 5 150 200 400 385 1100 Ambition 8 175 225 400...

Страница 22: ...22 2 8 Changing to back outlet 2 3 5 4 6 DETAIL D SCALE 1 1 5 1 4025 0007 1500 001146...

Страница 23: ...the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an of fence to emit smoke from a chimney of a buil ding from a furna...

Страница 24: ...24...