Maximum
wood filling
5
Vermiculite
(stone)
4
8
The wood will then ignite within a very short time
(Typically 1 to 3 minutes). Once the fuel is Igni-
ted. Close the door and regulate the air back to
operating air. When the fire is well established,
you can now regulate the operating air to the
desired combustion level.
The nominal output Ambition 5 / Ambition 8:
4.9/6.5 kW is equivalent to a firing interval of
approx. 45/55 minutes at 61/69% open combu-
stion air and 1.2/1.8 kg of wood.
The door must be closed
during operation.
Ensure when refueling that the wood is not too
close, it will cause poorer combustion, less heat
out-put and lower efficiency.
The fuel load, must be maintained below the top
series of air holes and within the outer vent in
each side. Fig. 5.
When refueling be careful to place
the fuel into the combustion cham-
ber gently, (use the provided glove).
By not doing so you risk cracking or
breaking the vermiculite.
If there is reduced draft in the chimney, we re-
commend opening a window at stoking. This will
give better ventilation to the room and more oxy-
gen for combustion.
1.6
emptying the ash
It is advantageous to leave a layer of ash in the
bottom of the combustion chamber on top of
the grate as insulation.
Be careful when emptying the
ashes out. There can be hot
embers left for a long time.
Never empty ash into a combustible container.
1.7 reduced burning
The stove is, approved for intermittent use.
Never turn down the air down so much that there
does not come any flames from the tree. Wait to
close the air until the flames haveburnt out and
the tree is transformed into glowing charcoal.
If you are looking for less heat out-put, achieve
this by fueling with smaller volumes of wood and
a lower operating air. You may not completely
close the operating air during firing.
Be aware that the stove will naturally soot if the
operating air is too low. This is not good for the
environment. There is also a risk for the glass,
the chimney and other parts will become sooted.
By a combination of the above and possibly
burning damp wood. Can lead to high levels of
soot that it becomes sticky. Causing the sealing
of the door to tear off when opening the door
the next day.
Never use the stove if the
seals are loose.
1.8 explosion!!!
It is very important never to leave
The stove after start up or refueling,
before the fire is established.
(Typically
1/2 -1
minutes)
Explosion hazard may be possible, if filled with
too much wood on the stove and the air supply
is to low. As large amounts of gas are being de-
veloped and this may cause a flue gas explosion.
Warning!
One must always use cation around
the stove seen, as it gets very warm
during use. (In excess of 90° C).
Children should avoid contact with the stove.
Setting up a fence if you have small children may
be necessary.
Содержание Ambition 5
Страница 22: ...22 2 8 Changing to back outlet 2 3 5 4 6 DETAIL D SCALE 1 1 5 1 4025 0007 1500 001146...
Страница 24: ...24...