20
HE 5760 Operating Instructions
# 372449| Version 3.2
7.3 CAN network configuration
7.3.1 CAN address assignment
Each device in the CAN network is addressed with its CAN node number. The assignment of
the CAN addresses must comply with certain rules.
The HE 5760 control unit does not require a CAN address.
With the HE 5725 valve controls, a distinction is made between:
one HE 5725 per chamber, consecutive numbering, 1, 2, 3, ... 48
two HE 5725 per chamber, split numbering, 1, 25, 2, 26, ... 24, 48
HE 5725
HE 5725
HE 5725
HE 5725
CAN
1
2
3 . . . 48
Figure 12
CAN numbering 1 slave per chamber
HE 5725
HE 5725
HE 5725
HE 5725
HE 5725
HE 5725
CAN
1
25
26..
2..
24 48
Figure 13
CAN numbering 2 slaves per chamber