47
-
Parameter
Description
Spin Rate
Spin Rate of the motor (rpm) = frame rate (Hz) * 60
GPS
GPS (PPS) status
Lock
Lidar's internal clock is in sync with GPS PPS
Unlock
Not in sync
NMEA
(GPRMC/GPGGA)
NMEA status
Lock
After receiving a valid NMEA message
Unlock
Not receiving a valid NMEA message for over 2 s
PTP
PTP status
Free Run
No PTP master is selected.
Tracking
Attempting to sync with the selected PTP Master, but the absolute offset exceeds
the user-specified limit in Section 4.2 (Settings).
Locked
Absolute offset is within the user-specified limit.
Frozen (Holdover)
Attempting to recover the connection to the PTP master.