52
-
Parameter
Options
Description
Trigger Method
Angle-Based (default)
Time-Based
The way laser firings are triggered.
Angle-based
Lasers fire every 0.09° at 5 Hz, 0.18° at 10 Hz, or
0.36° at 20 Hz..
Time-based
Lasers fire every 50 μs
Reflectivity
Mapping
Linear (default)
Nonlinear Mapping
Linear
The Reflectivity field in Point Cloud Data Packets linearly
represents target reflectivity (0 to 255%).
Nonlinear
Increases the contrast in low-reflectivity regions, see Appendix IV
(Nonlinear Reflectivity Mapping).
Interstitial
Points Filtering
OFF (default)
ON
To mitigate the interstitial points.
Definition of interstitial points: when a beam partially hits on a front target's edge
and further hits on a rear target, the return signal can result in a false point
located between both targets.
Standby Mode
In Operation (default)
Standby
In Standby mode, the motor stops running and lasers stop firing.