25
-
Figure 2.9 Connecting Box (Back)
Port #
Port Name
Description
d
Trigger Port
Outputs external trigger signals for multi-sensor synchronization.
Connector (socket): Molex, LLC 5023520300
Recommended wire connector (plug): Molex, LLC 5023510300
Voltage: 0 to 3.3 V
Signal type: pulse
Max. current output level: 12 mA
Pin Description for the trigger port:
Pin #
Direction
Pin Description
1
Input
GND, to ground the external trigger signal
2
Output-Encoder
Trigger signal: outputs one pulse when the lidar rotates 0.05°
Pulse width: 7 μs @ 600 RPM, 3.5 μs @ 1200 RPM
3
Output-Index
Trigger signal: outputs one pulse when Channel 18 passes the lidar's 180° position (see Figure 1.4)
Pulse width: 4 μs @ 600 RPM, 2 μs @ 1200 RPM