background image

1J

4

Selecting the Appropriate Faceplate Option

I

nches [mm]

1N 

1ND

1KD

1KM

CL

= center line     (2nd Line = centerline of faceplate opening)

(4-7/8” x 1-1/4” Square Corner)

1NM

1NTD

1K

OPTION 

DESCRIPTION 

1500  1600 

1J 

For Use With:

 

Cylindrical locksets with up to ¾” throw and all locksets with center-lined bolts. 

Compatible With:

  All brands of cylindrical latchbolts 

1K 

For Use With:

 

Mortise locksets with up to ¾” throw latchbolt. 

Compatible With:

  Baldwin, Marks, PDQ 

1KM 

For Use With:

 

Mortise locksets with up to ¾” throw latchbolt. 

Compatible With:

  Accurate, Arrow, Best, Corbin Russwin, Falcon, Sargent (7800, 8200, and 9200), 

Yale (8800) 

1KD 

For Use With:

 

Mortise locksets with up to ¾” throw latchbolt. 

Compatible With:

  Dorma (9500), Jackson, Sargent (7700 and 8100), Schlage, Yale (8700) 

1N 

For Use With:

 

Mortise locksets with deadbolt for night latch function only. 

Compatible With:

  Accurate, Baldwin, Marks, Omnia, PDQ, Schlage 

 

1NM 

For Use With:

 

Mortise locksets with deadbolt for night latch function only. 

Compatible With:

  Accurate, Arrow, Baldwin, Best, Corbin Russwin, Falcon (45H, 47H, 34H, and 

37H), Marks, PDQ, Sargent (7800, 8200, and 9200), Yale (8800) 

 

1ND 

For Use With:

 

Mortise locksets with deadbolt for night latch function only. 

Compatible With:

  Sargent (7700 and 8100), Schlage, Yale (8700) 

 

1NTD

 

For Use With:

 

Mortise locksets with a normally extended 1” deadbolt and center-lined deadlatch. 

Compatible With:

  Accurate, Arrow, Baldwin, Marks, Omnia, PDQ, Schlage 

 

 

Frame prep

3086006.001 Rev 3

Содержание 1500 Series

Страница 1: ...ing for the product and wiring methods shall be in accordance with the National Electrical Code ANSI NFPA 70 NOTE The above table applies to Models 1500 1500E 1600 and 1600E Input voltage 10 30 VDC Autosensing Ratings Static Strength 1 500 lbs Dynamic Impact 70 ft lbs Endurance 250 000 cycles Minimum Activation Duration 1 second 0 010A 0 009A 0 005A 0 004A ELECTRICAL RATINGS FOR 1500 1600 Solenoid...

Страница 2: ...USE the pigtail marked 24 VDC Purple and Black Wires Red and Black Wires Converting the Operation Mode IMPORTANT NOTE Converting the electric strike to FAIL SAFE mode negates the unit s fire rating NOTE 1 The 1500 and 1600 Series Electric Strikes ship configured for FAIL SECURE OPERATION The steps below are provided to convert to FAIL SAFE OPERATION if desired The operation mode of the 1500E and 1...

Страница 3: ...8 4 1 8 3 1 2 5 8 1 1 4 Mortise Lockset C L Strike C L Strike Prep 5 8 1 1 4 Cylindrical Lock C L C L STRIKE LOCK Vertical Centerline 2 1 4 1 1 4 1 3 4 Please note the horizontal centerline of the electric strike in relation to the centerline of the mortise lockset Please note the horizontal centerline of the electric strike in relation to the centerline of the cylindrical lockset 203 2 mm 101 6 m...

Страница 4: ... For Use With Mortise locksets with up to throw latchbolt Compatible With Dorma 9500 Jackson Sargent 7700 and 8100 Schlage Yale 8700 X X 1N For Use With Mortise locksets with deadbolt for night latch function only Compatible With Accurate Baldwin Marks Omnia PDQ Schlage X 1NM For Use With Mortise locksets with deadbolt for night latch function only Compatible With Accurate Arrow Baldwin Best Corbi...

Страница 5: ...c strike to open keeper STEP 1 LOOSEN the locking screw with the 5 64 Hex Wrench STEP 2 ADJUST the shim height to the desired level by turning the upper and lower set screws clockwise to raise and counterclockwise to lower STEP 3 TIGHTEN the locking screw to lock position 3086006 001 Rev 3 ...

Страница 6: ...hett Entry Systems Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Hanchett Entry Systems Inc is prohibited HES Inc Phoenix AZ 800 626 7590 www hesinnovations com ...

Отзывы: