BA HD140 V30 R20 07_2021 DE-GB.doc 

 

 

HERZ 

 
 
 
 
 
 
 
 
 
 
 
 

 

HERZ

 Hochdruckgebläse – Betriebsanleitung 

 

HERZ

 high-pressure blowers – Operating instructions

 

 
 

 

 
 
 

 

HERZ

 

GmbH

 

 

Biberweg 1, D-56566 Neuwied 

T49 (0)26 22 / 88 550 

Telefax 1 +49 (0)26 22 / 88 55 135 
Telefax 2 +49 (0)26 22 / 88 55 136 

Internet http://www.herz-gmbh.com 

E-mail: [email protected]

 

 

Содержание HD140

Страница 1: ...gebläse Betriebsanleitung HERZ high pressure blowers Operating instructions HERZ GmbH Biberweg 1 D 56566 Neuwied Telefon 49 0 26 22 88 550 Telefax 1 49 0 26 22 88 55 135 Telefax 2 49 0 26 22 88 55 136 Internet http www herz gmbh com E mail info herz gmbh com ...

Страница 2: ...de giftige explosionsfähige oder sehr feuchte Medien ist nicht zulässig Die zulässige Fördermedientemperatur für die Standardausführung beträgt 20 C bis 40 C Im Fördermedium enthaltene Feststoffe oder Verunreinigungen müssen vor Eintritt in den Seitenkanalverdichter ausgefiltert werden Der Seitenkanalverdichter ist ohne besondere Maßnahmen nicht für die Aufstellung im Freien geeignet Der Seitenkan...

Страница 3: ...zu keiner unzulässigen Erhöhung der Umgebungstemperatur über max 40 C am Antriebsmotor führen 1 10 Keilriemenantrieb betrifft nur Seitenkanalverdichter ohne Motor Hinweis Die Seitenkanalverdichter sind serienmäßig mit Keilriemenscheiben für Schmalkeilriemen nach DIN 7753 ausgerüstet Um vorzeitige Schäden an den Rillenkugellagern zu vermeiden müssen die Keilriemenantriebe richtig vorgespannt sein D...

Страница 4: ...r Kunde oder Betreiber alleine 3 2 Aufstellen Montage Seitenkanalverdichter vor Witterung geschützt horizontal aufstellen siehe auch 1 1 Bei Außenaufstellung ist generell ein Witterungsschutz vorzusehen der die Vorgaben unter 1 1 Bestimmungsgemäße Verwendung erfüllt und den Seitenkanalverdichter vor Wettereinflüssen schützt Keinen Schwing oder Stoßbelastungen aussetzen Zulässige Schwingungswerte S...

Страница 5: ...trisch niederohmig mit dem Erdsystem verbunden sein Auf der Motorseite sind hierzu geeignete EMV Kabelverschraubungen zu verwenden die den Kabelschirm am ganzen Umfang niederohmig kontaktieren Weitere Informationen zur EMV gerechten Installation und Montage sind den Hinweisen in den Betriebs und Montageanleitungen des Frequenzumrichterlieferanten zu entnehmen 3 3 1 Schaltung für Drehstrom Seitenka...

Страница 6: ...ungsursache zulässig Bei Seitenkanalverdichtern die nicht über die ganze Kennlinie einsetzbar sind kann bei zu großem Anlagenwiderstand der Motor überlastet werden zu hohe Stromaufnahme Wenn eine Überlastung aufgrund des Anlagenwiderstandes nicht ausgeschlossen werden kann ist ein Druckbegrenzungsventil vorzusehen Saug bzw Druckseite Der Seitenkanalverdichter darf keinen Schwing oder Stoßbelastung...

Страница 7: ...g geschulten Personen ausgeführt werden Dabei ist zusätzlich zur Betriebsanleitung des jeweiligen Gerätes sowie den Vorschriften und Empfehlungen der gesamten Anlage folgendes zu beachten Inspektions und Wartungsintervalle In Abhängigkeit von Betriebsstunden Belastungen und Einsatzbedingungen hat der Betreiber das Reinigungs Inspektions und Wartungsintervall selbst festzulegen Sofortige Inspektion...

Страница 8: ...SSERBETRIEBNAHME UND ABBAU Das Trennen aller elektrischen Verbindungen und aller weiteren elektrotechnischen Maßnahmen in Verbindung mit der Außerbetriebnahme darf nur von einer Elektrofachkraft ausführt werden Der Abbau ist erst zulässig wenn alle rotierenden Teile den Stillstand erreicht haben und ein Wiederanlauf nicht mehr möglich ist Zum Abbau und Abtransport müssen die Vorgaben aus 2 1 Trans...

Страница 9: ...or the standard version is 20 C to 40 C Solid particles or contaminants must be removed by a filter unit before entering the side channel blower The blower is not suitable for installation outdoors without special measures The blower is fundamentally designed for S1 operation continuous operation However a maximum of 30 switching operations per hour are permitted The standard version of the blower...

Страница 10: ...ive Only applies to side channel blower without motor Note The side channel blowers are equipped as standard with V belt pulleys for narrow V belts according to DIN 7753 To avoid premature damage to the deep groove ball bearings the V belt drives must be correctly pretensioned The V belt drive must be rated using the calculation method specified by the belt manufacturer The blower belt pulley must...

Страница 11: ...ibrations or shocks Permissible vibrational load on side channel blower refer to ISO 14694 BV 3 Standard side channel blowers with base Bolt securely to a level and fi rm surface at the place of use making sure that the surface has adequate load bearing capacity and avoiding vibration transmission or vibrational load Side channel blowers placed on the rubber elements provided must be secured again...

Страница 12: ...lectric shocks fi res property damage and personal injuries Check for loose connections and tighten in accordance with the tightening torques in the following table circuit low voltage Y circuit high voltage Threaded bolt Tightening torque M4 1 2 Nm M5 2 0 Nm M6 3 0 Nm M8 6 0 Nm Checking the direction of rotation Switch on the side channel blower The running direction of the impeller should corres...

Страница 13: ...m resistance cannot be excluded a pressure limiting valve must be provided on the intake or pressure side The side channel blower must not be subjected to vibration or impact loads 4 2 Frequency converter operation A frequency converter is used allowing a wide range of speed adjustments There is only a small load related difference in rpm between idle state and the max load of the side channel blo...

Страница 14: ...d Note Repairs must be carried out by the manufacturer We cannot accept any liability for modifications or the replacement of components carried out by third parties 5 1 Ball bearings Note The side channel blowers from HERZ are equipped with sealed deep groove ball bearings which do not require relubrication Note Check the ball bearings during servicing and prior to recommissioning Operation is on...

Страница 15: ...emoving it Treat the device as industrial waste when disposing of it The device parts are made of recyclable material such as aluminium stainless steel copper and plastic However there are components that need special treatment e g frequency converters The statutory national and local disposal and recycling regulations must be observed 7 0 LIABILITY AND EXCLUSION OF LIABILITY The owner shall bear ...

Страница 16: ...16 Technische Änderungen vorbehalten Technical changes reserved BA HD140 V30 R20 07_2021 DE GB doc ANHANG APPENDIX A ...

Страница 17: ...BA HD140 V30 R20 07_2021 DE GB doc Technische Änderungen vorbehalten Technical changes reserved 17 ANHANG APPENDIX B ...

Страница 18: ...14 30 EU Directiva de baja tensión 2014 35 EU Directiva de Máquinas 2006 42 EG Normas armonizadas DIN EN 12100 2011 EN 60034 1 2011 EN 60034 5 2007 EN 60204 1 2019 EN 60664 1 2008 EN 60034 30 1 2014 _____________________________ Oliver Adrian Gerente Neuwied 01 07 2021 Português Declaração de conformidade HERZ GmbH D 56566 Neuwied Rhein confirma que este produto deste modelo posto em circulação po...

Страница 19: ...s DIN EN 12100 2011 EN 60034 1 2011 EN 60034 5 2007 EN 60204 1 2019 EN 60664 1 2008 EN 60034 30 1 2014 _____________________________ Oliver Adrian Įmonės vadovas Neuwied 01 07 2021 Latviešu Atbilstības deklarācija HERZ GmbH D 56566 Neuwied Rhein apliecina ka šis mūsu apgrozījumā nodotais modeļa izstrādājums atbilst visām sekojošo EK direktīvu prasībām Instrumenta apraksts Sānu kanāla kompresors Ti...

Страница 20: ...60034 30 1 2014 _____________________________ Oliver Adrian Управител Neuwied 01 07 2021 Eesti Vastavusdeklaratsioon HERZ GmbH D 56566 Neuwied Rhein kinnitab et see toode täidab meie poolt ringlusse toodud kujul järgmiste EÜ direktiivide nõuded Tööriista nimetus Side kanaliga kompressor Mudel HD140 Direktiivid EMC direktiiv 2014 30 EU Madalpingedirektiiv 2014 35 EU Masinad direktiivi 2006 42 EG Ha...