9
Fault Reports and their correction
54
Betriebsanleitung_firematic_20-301_Touch_Englisch V1.2
Fault reporting on the display
Possible cause?
Suggestions for rectifying
F: DATAERROR MEMORY
INTERNAL
Error in the adjustment data in
an internal module
•
Contact
your
specialist
installer.
FAULT 50
F: DATAERROR MEMORY BOILER Error in the adjustment data in
the boiler module
•
Contact
your
specialist
installer.
FAULT 51
F: CLAMPING UNIT
Sensor on the clamping unit
defective
or break in sensor cable
or plug not inserted correctly
•
Contact
your
specialist
installer.
FAULT 52
F: ADDITIONAL FLUE GAS
SENSOR
Flue gas temperature of the
additional boiler does not fit.
•
Control
the
flue
gas
temperature of the additional
boiler
FAULT 53
F: EXTERNAL SET POINT
Sensor at external temperature
defective
or break in sensor cable
or plug not inserted correctly
•
Renew the sensor
FAULT 54
F: BACK FLOW SET
Back flow set temperature could
not be reached in operation
•
Control the back flow set
FAULT 55
F: SCREED BAKE OUT
Error in the screed bake out
process. Flow-must temperature
could not be achieved.
•
Control
the
flow
must
temperature
FAULT 56
F: CHECK DATA MODUL
A module parameter is not in the
specified range.
•
Control
the
module
parameter
FAULT 57
F: CHECK DATA BOILER
A boiler parameter is not in the
specified range.
•
Control the boiler parameter
FAULT 58
F: MAINTENANCE
•
Contact
your
specialist
installer.
FAULT 59
F: INSERTION IN ACTION
Feed screw temperature too high
when in operation
•
Contact
your
specialist
installer.
FAULT 60
F: INSERTION NOT IN ACTION
Feed screw temperature too high
when out of operation
•
Contact
your
specialist
installer.
FAULT 61
F: INSERTION BACKFIRE
Feed screw temperature still too
high after 15 minutes safety time
•
Contact
your
specialist
installer.
FAULT 62
F: OPEN BFP
when opening the BFP damper
•
Contact
your
specialist
installer.
FAULT 63
F: CLOSE BFP
Fault when closing the BFP
damper
•
Contact
your
specialist
installer.
FAULT 64
F: CONTACTS BFP
Fault in BSD contacts (both limit
switches are closed at the same
time)
•
Contact
your
specialist
installer.
•
RSE überprüfen lassen.
FAULT 65
F: IGNITION
Ignition failure
Heat generator ignition failed 3
times
•
Check the fill level of the
pellet store and top up if
necessary.
•
Contact
your
specialist
installer if the pellet store fill
level is sufficient and the fault
keeps occurring.
FAULT 66
F: FIRE OUT
Flame
monitoring
device
indicates Fire has gone OUT
•
Contact
your
specialist
installer.
FAULT 67