T-Control
8
Betriebsanleitung_commotherm_5_15_SW_WW_Touch_Englisch_V1.2
37
bu
ff
er
H
ea
t
pu
m
p
H
ot
w
at
er
ta
n
k
H
ea
ti
n
g
c
ir
cu
it
T
im
e
m
od
e
S
ol
ar
H
yd
r.
c
o
m
pe
ns
.
Z
on
e
va
lv
e
N
et
p
um
p
E
xt
.
re
qu
ir
em
en
t
Term
Description
Unit
Status I
Flow temperature
Indicates the flow temperature of chosen heating circuit
°C
Back flow temperature Indicates the back flow temperature of chosen heating circuit
°C
Outside temperature
Indicates the actual outside temperature
°C
Room temperature
Indicates the room temperature
°C
Room correction
Indicates the room correction
°C
Status II
Switching temperature
Indicates the switching temperature (= average daytime temperature). In
general the switching temperature conducts the switching between
winter set temperature and summer set temperature.
°C
Heating circuit mixer
Indicates the state of the heating circuit mixer (OPEN/CLOSE)
-
Heating circuit pump
Indicates the state of the heating circuit pump (ON/OFF)
-
Screed days
Setting up screed drying heat day
Only visible, if operation mode “screed drying“ is activated
-
Operation modes
Heating circuit
Activation heating circuit (ON/OFF)
-
Operation mode
Selection operation modes:
Heating time mode:
Heating corresponds to the set heating time
Durable heat:
Constant heat up to required set room temperature or to the
calculated feed flow target temperature
Durable kneeling:
Constant heat up to setback temperature respectively calculated flow
temperature during setback time
Flow fixed:
A defined feed flow set temperature will be held constantly during the
set heating time.
Remote control:
Modus corresponds to the remote control setting. Only available, if
remote control is connected.
Screed drying:
Modus of screed drying. The operation of the screed drying is
described on pages 37-38.
-
Actual heating circuit
mode
Indicates the actual heating circuit operating mode
-
Remote control
number
Selection of heating circuit´s remote control
-
Balancing room
sensor
Setting up balancing room sensor (-5 to +5)
°C
Kneeling barrier over
room temperature
Activates the kneeling barrier (ON/OFF)
only possible with remote
control:
If actual room temperature is higher then set room temperature, the
option „ Kneeling barrier over room temperature “ provides a lock of
the heating circuit.
-
Parameter I
Room must
temperature
Setting up the required room temperature during heating time. This
setting is only used in connection with a remote control (FBR 1)
°C
Kneeling temperature
Setting up required room temperature during lowering time.
°C