HERZ Wireless control system
•
Combination 2: Re RF Ther RF Central unit for heating regulation
(1) First step is to pair the RF thermostat to the Central unit.
(2) Press the RF button on the receiver during 5 sec.
(3) The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration mode
waiting for a central configuration address.
(4) Please refer to the leaflet of the Central unit for more explanation about the pairing mode
“rF Init”
. You must pair
the Receiver as a heating device in the Central unit.
(5) The RF LED on the receiver will switch
OFF
and the Central will show a message to indicate correct pairing
between both elements.
•
Installation 3: Re RF Central unit for ON/OFF or light control
(1) Press the RF Button 5 sec to switch the Receiver in
“rF Init”
mode.
(2) The RF LED should be Green fixed or orange blink indicating that the Receiver is now in radio configuration mode
waiting for a central configuration address.
(3) Please refer to the leaflet of the Central unit for more explanation about the pairing mode
“rF Init”
. You must pair
the Receiver as an ON/OFF plug or a light in the Central unit.
(4) The RF LED on the receiver will switch OFF and the Central will show a message to indicate correct pairing
between both elements.
You can pair several receivers to the same RF thermostat.
Note for installations 2 and 3: You can pair several receivers. Pay attention! Before linking a new receiver with the
central unit, you have to reset the receiver imperatively.
For safety reasons and to simplify the installation, it is recommended to connect only one radiator to the radio receiver.
Further radiators or heating loops are to be connected by separate radio receivers, which can be connected to the