Page 18
HERZ Wireless control system
parameter
advanced installation menu
Number
Description
Description of the values
Factory settings
other Possibilities
24
RecS - - -
View of the measured values of
the floor sensor connected to the
receiver.
“- -.- “
25
FL.Lo - - -
Lower limit of the floor temperature
„No
“
The lower limitation is
not used.
From 5 °C to
„FL.Hi“
26
FL.Hi - - -
Upper limit of the floor
temperature.
„No“
The upper limitation is
not used
From
„FL.Lo“
to
40 °C
27
reg - - -
Selection of regulation type
„bp“
Proportional band
(PWM)
„hys“
Hysteresis (On/Off)
28
Bp1 - - -
screed choice.
„uf1“
For liquid screed with
low thickness
< 6cm
„uf2“
For traditional
screed with
thickness
> 6cm
29
Bp2 - - -
Floor covering choice.
„Fl1“
For tiles
„Fl2“
For wood parquet
(floating or not)
30
wir
Pilot wire function for French
Market application:
Use this option if your installation
has the pilot wire installed in
combination with an energy saver.
„Yes“
Function activated
„No“
Function
deactivated
31
min
Minimal value of the setting range
„5,0 °C“
„15,0 °C“
32
max
Maximal value of the setting range
„20,0 °C“
„37,0 °C“
33
Win
Automatic open window detection.
(See user guide for more
explanation)
„Yes“
Function activated
„No“
Function
deactivated
34
Clr EEp
All parameters will be reloaded
with the factory value.
Press on the
(OK)
key during few seconds
35
End
To exit the installer’s menu
Press on the
(OK)
to exit.