background image

T1 (Gen 3) WIRELESS THERMOSTAT 

Program Mode 

The T1 has a 7 x 1 day timer (Monday to Sunday) with 

4  periods  per  day.    Set  Period  1  as  the  temperature 

for  the  morning.  Period  2  is  the  fallback  temperature 

for  the  daytime.  Period  3  is  the  temperature  required 

for  the  evening  and  period  4  is  the  overnight 

temperature. 

Unlike  conventional  heating,  Herschel  Far  infrared 

directly  heats 

the  room  (the  “Thermal  Mass”).  For 

areas  in  frequent  use  it  is  more  economical  to  avoid 

temperatures dropping too low as the heater will need 

to  be  on  for  a  much  longer  period  to  restore 

temperatures.    We  recommend  overnight  setback 

temperatures  of  no  lower  than  14°C  and  daytime 

temperatures of 16°C and above.   

To  select  Program  Mode  press  MENU  until  PRG  is 

displayed as the mode. The schedule will then operate 

until another mode is selected. 

 

To set the 7 days program 

The default program you will receive with your T1 is: 

To alter this schedule: 

 

Press the PRG button for 3 seconds to start the 7 

x  1  day  program  setting.  The  First  period  of  the 

First day is selected. 

 

All days 

Period 1 

 

0600 20

           

 

Period 2 

0900 16

           

Period 3 

16:00 20

 

Period 4 

23:00 16

 

 

Press the Up or Down button to change the time of 

the first period of the day’s program. 

 

Press  PRG  again  to  move  to  the  temperature 

setting of the first period and use the Up and Down 

buttons to adjust the temperature. 

 

Press PRG again to move to the second period of 

the  first  day’s  program.  Repeat  the  above 

procedure to finish setting the other periods of the 

first day’s program. 

 

Press PRG again to move to the first period of the 

second day. 

 

Once setup is complete, press Return to get back 

to the main display.   

Temperature  can  always  be  overridden  manually  by 

pressing  the  Up  and  Down  buttons.  The  temperature 

will  remain  at  this  setting  until  the  next  programmed 

change  occurs.  For  example,  using  the  default 

schedule  in  the  previous  table,  if  it  was  18:00  on  a 

Monday  the  thermostat  would  be  set  to  20°C.  If  you 

wished to increase the temperature to 21°C, press the 

Up  button  to  increase  temperature  to  21°C.  The 

thermostat  would  then  retain  this  setting  until  23:00 

when  the  period  4  schedule  would  reduce  the  set 

temperature to 16°C. 

 

Parameter Settings 

The T1 has several special operating parameters you 

can set, these are: 

Temperature  Calibration

  to  adjust  the  unit  to 

compensate temperature up or down by up to 8°C. For 

example if you have another control in the room which   

Отзывы: