T1 (Gen 3) WIRELESS THERMOSTAT 

reads  differently  from  the  T1,  or  if  you  have  to  place 

the T1 close to the radiator and don’t want to have the 

T1  stop  the  heat  before  the  rest  of  the  room  has 

warmed up (negative adjustment needed). Or perhaps 

the T1 is placed in a cold area (e.g by a window) and 

you want the T1 to stay on less so the rest of the room 

does not overheat (positive adjustment needed). 

Open Window on / off 

Open Window is  an  energy saving feature. When the 

room temperature is 14°C and above, if the thermostat 

senses a fall in temperature of 2°C or more within a 15 

minute period, the T1 will turn off the heater(s) for one 

hour and 

“OP” will show in the display. This is to avoid 

wasting electricity where  a window or  door is likely to 

have  been  opened.  Whilst  you  can  always  override 

this  by  adjusting  the  temperature  Up  or  Down  or 

pressing  the  BOOST  button  on  the  R1,  you  can  also 

switch  off  the  function  totally  (see  how  to  change  the 

Parameter Settings below). 

Adaptive Start 

Adaptive  Start  is  another  energy  saving  feature 

designed  to  smooth-out    heating  consumption  when 

large  jumps  in  temperature  exist  between  the  current 

set  temperature  and  the  next  scheduled  temperature 

(implies  large  energy  use).  Herschel’s  adaptive  start 

function 

will 

compare 

the 

currently 

sensed 

temperature against the next scheduled setpoint and if 

the  difference is more than  5°C it will  start the heater 

earlier.  You  can  use  Parameter  Settings  to  turn  off 

Adaptive start totally. 

 

 

How change Parameter Settings: 

 

Turn off the T1. 

 

Press  MENU  and  UP  button  together  for  3 

seconds. This brings up each available parameter 

in turn as shown in the table below. The parameter 

is changed by pressing the Up or Down button and 

the next parameter selected by pressing MENU. 

 

Failsafe Mode 

If the T1 is paired to the iQ Hub and fails to receive any 

commands  for  more  than  30  minutes,  the  T1  will 

operate on its current settings until a new command is 

received.   

If  the  T1  loses  signal  with  the  R1  for  more  than  30 

minutes, the R1 will default to 18°C. 

This  feature  ensures  that  heaters  can  still  operate 

sensibly  and  safely  in  case  of  failure  or  signal  issues 

with the hub or T1. 

 

 

Menu

 

Description   

 

Range 

Default 

01

 

Temp. 

calibration     

 

-8 

 

+8 

 

0

 

02 

Open Window   

0:Off   

1:On 

03 

Adaptive start 

0:Off   

1:On 

On 

04 

Software info. 

05 

Software info.   