MD2 WIRED THERMOSTAT

 

Dimensions (mm) 

       

The MD2 is 86mm x 86mm and the front display is 16.5mm thick. A single gang pattress box 46mm deep is 

required for mounting, and mounting holes are 60mm apart. 

 

Wiring 

Wiring the MD2 should be carried out by a qualified 

electrician. Ensure power supply to the MD2 is turned 

OFF  before  wiring  or  unwiring  the  MD2.  Maximum 

load is 16A / 3.6kw at 230v.     

 

The  MD2  can  be  used  to  control  several  Herschel 

heaters but the maximum wattage of 3.6kw (3,680w) 

must  not  be  exceeded.    Do  not  use  for  any  other 

non-Herschel heating devices. INDOOR USE ONLY. 

 

Wire mains Live to terminal 1, Neutral to terminal 2 and Earth to terminal 5. Wire the load to heater: Live to 

terminal 3,    Neutral to terminal 4 and earth to terminal 5.   

 

 

 

 

Содержание IQ MD2

Страница 1: ...day programming modes with 4 periods per day The MD2 will operate your Herschel heater s by turning them ON if the room temperature is lower than the desired temperature and will turn them OFF once th...

Страница 2: ...from the App Store or Google Play Alternatively search Smart Life on Google Play or the App Store look for this icon Operation using the SmartLife App The MD2 can be used stand alone or with the Smart...

Страница 3: ...king shows a solid connection Please note it may take up to a minute for the Controller to stop flashing after it appears to have paired successfully in the Smartflife App Tap the Thermostat in the ap...

Страница 4: ...pply to save energy e g on holiday or as a frost protection setting This setting can also be manually overridden Program mode is displayed as the number denotes which period of the day is active Any m...

Страница 5: ...and daytime temperatures of 16 C and above Always try to program the schedule so a room is at the temperature you want by the time you want For example if you want it to be 21 C by 0700 am consider s...

Страница 6: ...ess for 5 seconds to unlock the keypad for a temporary adjustment The keypad will lock again once the backlight on the display switches off Window Open Detect When temperatures are above 14 C if the s...

Страница 7: ...5 C 03 Min Temp setpoint 5 C 45 C 5 C 04 Sensor select 0 Room only 1 External only 2 Room External 0 Room only 05 Frost Protection Temp 5 C 15 C 5 C 06 Temp Calibration for external sensor 8 C 8 C 0 C...

Страница 8: ...nsure power supply to the MD2 is turned OFF before wiring or unwiring the MD2 Maximum load is 16A 3 6kw at 230v The MD2 can be used to control several Herschel heaters but the maximum wattage of 3 6kw...

Страница 9: ...0 5 step control by 0 5 Protection Class IP30 Housing ABS to UL94 5 fire retardant plastic Certifications EN60950 Information Equipment Safety EMC ETSI EN301 489 Radio ETSI EN300220 EMC EN61000 6 3 20...