MD2 WIRED THERMOSTAT
Temperature can always be overridden manually by pressing the
and
buttons.
The
temperature will remain at this setting until the next programmed change occurs.
For example, using the above table, if it was 18:00 on a Monday, the thermostat would be set to 21°C. If you
wished to increase the temperature to 22°C, press
to increase temperature to 22°C. The
thermostat would then retain this setting until 22:30 when the period 4 schedule would reduce the set
temperature to 16°C.
Keypad Lock
The Keypad Lock function can be selected On or Off in the parameter settings (see Parameter Settings below).
It is Off by default. Keypad lock is indicated by a Padlock at the top left of the display.
You can press
for 5 seconds to unlock the keypad for a temporary adjustment. The keypad will
lock again once the backlight on the display switches off.
Window Open Detect
When temperatures are above 14°C if the system detects a drop of 2°C in a 15 minute period, the heating will
automatically be stopped (if it is on). The letters
OP
will display instead of the temperature display. The MD2
will return to the previous mode of operation after 60 minutes and the current room temperature will replace
the letters
OP
once again. Pressing any button during the 60 minute period will exit the Open Window function
and resume previous operations.
Window Open is set OFF by default when you receive the MD2. In Parameter Settings, you can enable the
Window Open Detect function; change the temperature drop detected; change the period within which the
drop is detected and change the period the heater remains off. See Parameter Settings.