background image

MD2 WIRED THERMOSTAT

 

 

Program Mode 

The MD2 has a 7 x 1 day timer (Monday to Sunday) with 4 periods per day.    For example, you could choose 

Period 1 to be the temperature you wake-up to; Period 2 the daytime set-back temperature; Period 3 the late 

afternoon / early evening temperature and Period 4 the nighttime setback temperature. 

Unlike conventional heating, Herschel Far infrared directly heats the room (the “Thermal Mass”). For areas in 

frequent use it is more economical to avoid temperatures dropping too low as the heater will need to be on for 

a much longer period to restore temperatures.    We recommend overnight setback temperatures of no lower 

than 14°C and daytime temperatures of 16°C and above. Always try to program the schedule so a room is at 

the temperature you want by the time you want. For example if you want it to be 21°C by 0700 am, consider 

starting the program at 0600 a.m. 

 

To set the 7 days program 

 

Press 

for  3  seconds  to  start  the  7  x  1  day  program  setting. The  First  period  of  the  First  day  is 

selected. 

 

Press 

  or 

  to set the time of the first period of the day’s program. 

 

Press   

and

 

 

to select the desired temperature setpoint.   

 

Press 

again to proceed to the next period.

 

 

Repeat the above procedure for each period of each day. 

The default settings you will receive with your MD2 are as follows: 

 

 

 

 

 

To select Program Mode press 

until   

is displayed as the mode. 

The schedule will then operate until another mode is selected. 

 

All Days   

 

Period 1 

 

0630    21

     

 

Period 2 

0800    18

       

Period 3 

18:00    21

 

Period 4 

22:30    16

 

Содержание IQ MD2

Страница 1: ...day programming modes with 4 periods per day The MD2 will operate your Herschel heater s by turning them ON if the room temperature is lower than the desired temperature and will turn them OFF once th...

Страница 2: ...from the App Store or Google Play Alternatively search Smart Life on Google Play or the App Store look for this icon Operation using the SmartLife App The MD2 can be used stand alone or with the Smart...

Страница 3: ...king shows a solid connection Please note it may take up to a minute for the Controller to stop flashing after it appears to have paired successfully in the Smartflife App Tap the Thermostat in the ap...

Страница 4: ...pply to save energy e g on holiday or as a frost protection setting This setting can also be manually overridden Program mode is displayed as the number denotes which period of the day is active Any m...

Страница 5: ...and daytime temperatures of 16 C and above Always try to program the schedule so a room is at the temperature you want by the time you want For example if you want it to be 21 C by 0700 am consider s...

Страница 6: ...ess for 5 seconds to unlock the keypad for a temporary adjustment The keypad will lock again once the backlight on the display switches off Window Open Detect When temperatures are above 14 C if the s...

Страница 7: ...5 C 03 Min Temp setpoint 5 C 45 C 5 C 04 Sensor select 0 Room only 1 External only 2 Room External 0 Room only 05 Frost Protection Temp 5 C 15 C 5 C 06 Temp Calibration for external sensor 8 C 8 C 0 C...

Страница 8: ...nsure power supply to the MD2 is turned OFF before wiring or unwiring the MD2 Maximum load is 16A 3 6kw at 230v The MD2 can be used to control several Herschel heaters but the maximum wattage of 3 6kw...

Страница 9: ...0 5 step control by 0 5 Protection Class IP30 Housing ABS to UL94 5 fire retardant plastic Certifications EN60950 Information Equipment Safety EMC ETSI EN301 489 Radio ETSI EN300220 EMC EN61000 6 3 20...