![HERKULES G205 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/herkules/g205/g205_owners-manual_2126284008.webp)
Model Information
Parts bag contents
001-600A
S-hook
1 ea.
001-705
Flat washer 1/4
2 ea.
001-702
Hex bolt 1/4-20 x 1/2
16 ea.
002-161
Flat washer #10
19 ea.
002-175
Bolt BHSC 10-24 x 3/4
2 ea.
005-137
Nut hex 10-24 - nylock
2 ea.
008-244
Acorn nut 1/4-20
18 ea.
6
Ball valve
1 ea.
83
Hex bolt 1/4-20 x 1
2 ea.
84
Hex nut 1/4-20
2 ea.
85
Lock Washer 1/4
20 ea.
1000652
Clevis pin 1/4 dia.
1 ea.
1000252
Cotter pin
1 ea.
1000116
Hex bolt 1/4-20 x 5/8
2 ea.
11957
Actuator
1 ea.
C9A
Nipple 1/8 NPT X 4-1/2
2 ea.
53B
Stem support female
2 ea.
M5
Tube 5/32 blue plastic
30 in.
M5-BLACK
Tube 5/32 black plastic
9 in.
M5-NEUTRAL Tube 5/32 clear plastic
13 in.
NOTE:
Dimensions listed are overall measurements.
Model
Description
Weight
Dimensions in. (mm)
(kg.)
A
B
C
D
G205
Two gun, two cup paint gun washer equipped with
68
46
20.625
24.5
21.25
a solvent transfer system
(31)
(1168)
(524)
(622)
(540)
Installation
Installing the Gun Washer
1)
Place gun washer on a level surface in a properly
ventilated paint mixing room or paint booth.
Grounding the Gun Washer
1)
Connect the ground wire on the gun washer’s pump to a
true earth ground.
2)
Ground all equipment used or located in the gun washer
area.
Connecting the Air Line
1)
Install a 1/4 in. npt male coupler, that is compatible with
the quick disconnect of your air supply line, into the air
supply port of the filter/regulator located on the right rear
leg (see fig. 9).
2)
Connect air line with at least 75 psi to the coupler.
Filter/regulator is preset. Do not adjust.
Air supply
port
fig.9
A
B
C
D
Page 8 of 20