![HERKULES G205 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/herkules/g205/g205_owners-manual_2126284007.webp)
Assembly
Connecting lid rod and actuator linkage
STEP 12
Slide the actuator over the lid rod opposite the drilled end and
hand tighten approx. 4" from the end of the rod. Insert the
actuator into the large slot in the right rear leg (see fig 8).
STEP 13
Attach the lid rod to the lid bracket using the 1/4" clevis pin
and circular cotter pin supplied (see fig. 7).
STEP 14
To adjust the actuator, close the lid and loosen the set
screw on the actuator. Slide the actuator down until it
completely closes the limit valve and retighten the set
screw (see fig. 8).
Grounding the lid
STEP 15
Using an 1/8" allen wrench, remove the back right lid screw.
Connect the ground wire (with the aluminum terminal
attached) from the pump to the lid screw and reconnect it
to the tub (see fig. 7).
fig.7
Lid screw
Ground wire
Lid rod
Cotter pin
Lid bracket
Clevis pin
fig.8
Lid rod
Actuator
Set screw
Page 7 of 20