1.2.16. Keep the hot parts of the heater at
an adequate distance from inflammable
or termolabile materials (including the
power supply cable).
►
1.2.17. If the power supply cable is
damaged, it must be replaced by the
technical after-sales centre, in order to
prevent all risks.
2. UNPACKING
►2.1. Remove all packaging materials used
to wrap and deliver the heater and dispose
of them in compliance with the Standards in
force.
►2.2. Extract all articles from the packaging.
►2.3. Control for any damage undergone
during transport. If the heater appears
damaged, inform the dealer, where the
purchase was made, immediately.
3. ASSEMBLY (29-44 kW)
(SEE FIG. 1)
These models have wheels and handle/s de
-
pending on the model. These components,
complete with relative nuts and bolts, are situ
-
ated in the heater box.
4. FUEL
WARNING: The heater only functions
with DIESEL or KEROSENE.
Only use diesel or kerosene, to prevent the
risk of fire or explosion. Never use petrol,
naphtha, solvents for paints, alcohol or other
highly inflammable fuels.
Use non-toxic anti-freeze additives in the case
of very low temperatures.
5. FUNCTIONING PRINCIPLES
(SEE FIG. 2)
A. Combustion chamber and heads,
B. Fan,
C. Motor,
D. Compressor,
E. Tank.
The compressor (D) started by the motor
(C) compresses the air, which through the
atomising nozzle, sucks up the fuel from the
tank (E) due to the “VENTURI EFFECT”. On
contact with the igniter, the atomised fuel
ignites inside the combustion chamber (A).
The combustion products are mixed with the
flow of room air generated by the rotation of
the fan (B) and pushed towards the outside
of the heater. A photoresistance, connected to
a circuit board, constantly checks the correct
functioning of the heater, stopping the cycle in
the event of anomalies.
6. FUNCTIONING
WARNING: Thoroughly read the
”INFORMATION REGADRING SAFETY”,
before switching the heater on.
►►6.1. SWITCHING THE HEATER ON:
►6.1.1. Follow all instructions relative to
safety.
►6.1.2. Check the presence of fuel in the tank.
►6.1.3. Close the tank cap.
►6.1.4. Connect the power supply plug to
the mains electricity (SEE VOLTAGE IN
“TECHNICAL DATA TABLE”) (SEE FIG. 3).
►6.1.5. Take the “ON/OFF” switch to the
“ON” (|) position (SEE FIG. 4). The heater
should switch-on within a few seconds. If
the heater does not start, consult the “13.
TROUBLESHOOTING” paragraph.
►6.1.6. For the models with room thermostat,
check the position of the knob (SEE FIG.
9-10).
N.B.: IF THE HEATER SHOULD SWITCH-
OFF DUE TO THE LACK OF FUEL, TOP-UP
THE TANK AND RESET THE HEATER (SEE
PAR. 6.2).
►►6.2. RESETTING THE HEATER:
In the models with automatic “RESET”, switch
the heater off and back on again (SEE FIG.
5-4).
►►6.3. SWITCHING THE HEATER OFF:
DO NOT PULL THE PLUG OUT UNTIL THE
COOLING CYCLE HAS TOTALLY ENDED.
►6.3.1. Take the “ON/OFF” switch to the
“OFF” (O) position (SEE FIG. 5).
►6.3.2. Disconnect the heater from the mains
electricity (SEE FIG. 6).
7. REGULATING THE PRESSURE
OF THE COMPRESSOR (Contact the
technical service center)
(
SEE FIG. 7)
THE COMPRESSOR PRESSURE MAY
HAVE TO BE RESTORED WITH WEAR OF
THE HEATER.