S
AFETY
I
NSPECTION
33
11.1
Regular Safety Check
(In accordance with §10 ( 2 ) German Health and Safety regulations !)
Device type
Serial number
Inspection result
Start-up not permitted, verification required
Start-up possible, faults to be rectified by: ...............................................
No fault, start-up possible immediately
Safety inspection performed on:
……………………………………................................................
Name and address of qualified personnel
............................................................................................
…………………………………………
………………………………………..
Signature of competent person
Signature of operator
With the required rectification of faults
…………………………………………
………………………………………..
Signature of competent person
Signature of operator
Inspection step
OK
No
t O
K
re
-
ex
amin
ati
on
Remark
Nameplate
Sign with lifting capacity
Sign with bar mains pressure
Operating instructions (abbreviated)
Designation lift - lower
Secure fit of all supporting screws
Safeguard of the scissor pins
condition of the pneumatic lines
safety valve set to 3.5 bar operating pressure
Pressure gauge bar mains pressure P
max
= 8 bar
Control lever returns automatically to the '0' position when
released
Safety catch function
Loading ramps function
Interim drive over ramp function (
only HLS1200-11
)
Roll-off protection function
Protective flaps function (
only HLS1200-14
)
Condition of the air bags
Condition of the supporting structure
Condition grounding line
(only HLS1200-14-16)
Functionality of the service lift with vehicle
Содержание HLS 1200-11
Страница 40: ...ADDITIONAL INFORMATION 40 Dimensions Installation Pit HLS1200 14 16...
Страница 41: ...ADDITIONAL INFORMATION 41 Dimensions Substructure HLS1200 14 16...
Страница 42: ...ADDITIONAL INFORMATION 42 Schematic Diagram Installation HLS1200 14 16...
Страница 43: ...ADDITIONAL INFORMATION 43 Dimension Sheet HLS 1200 11...
Страница 44: ...ADDITIONAL INFORMATION 44 Dimension Sheet HLS 1200 14 16...