Maintenance Cont.
If your fitting begins to leak the following should be
carried out;
Isolate both hot and cold water supplies to the tap
by either:
•
Turning the water supply off at the mains
stopcock or
•
Turning off the isolation valves to the tap.
1. Unscrew the indice, to reveal the screw and
washer and proceed to remove these with a
suitable screwdriver.
2. Remove the handle and unscrew the shroud.
3. Using a suitable spanner remove the valve.
4. Replace the valves. Please visit
in order to find
spare parts for this product
5. Place the valve into the tap body, ensuring the
washer is in the required position, and tighten
the valve fully using a suitable spanner.
6. Re-connect the shroud, handle and all other
components.
7. Turn on water supply and check for leaks.
9. Contact our helpline should if problem persists.
Replacing the Valves
Handle
Indice
Tap Body
Shroud
Washer
Valve
Screw
&
Washer
Handle
Indice
Shroud
Screw & Washer
Valve
Washer
Tap Body
09