Fireplace endorsed
according
to
Regulation:
UNE-EN 13229:2001
“Insertable
appliances, including
open
fireplaces,
which use solid fuels
- Requisites and
testing
methods”,
modified by UNE-EN
13229/AC, UNE-EN
13229/A1:2003 and
UNE-EN
13229:2002/A2:2005
.
9. TECHNICAL INFORMATION
Power output to the env ironment (usable)
9 kW
Mass of load / hour
3 kg
Average gas temperature
350 ºC
Average concentration of CO at 13% O2
0,31
Performance
75%
T EST CERTIFICAT E NUMBER
LEE-014-09
NOT IFIED BODY NUMBER
NB 1722 (CEIS)
Takes logs with a length of:
400 mm.
Height
290 mm.
Front door::
Width
585 mm.
Smoke collar
150 mm.
φφφφ
Int.
Metal chimney
150 mm.
φφφφ
Int.
Recommended chimney height
5 a 6 metros
Approximate minimum brickwork chimney
200 x 200 mm.
Flue
Vertical
Recommended minimum flue
12 Pa
Primary air control
Manual regulation
Model C-10
120 Kg.
WARNING! Your insertable fireplace must not be used as an incinerator and no other fuels may
be used (plastics, coal etc). Use the recommended materials.
Recommended fuels:
Fuel
Size L x Ø
Maximum load weight per hour
Beech
40cm x 7cm (aprox.)
3 Kg.
Holm oak
40cm x 7cm (aprox.)
3 Kg.
Pine
40cm x 7cm (aprox.)
3 Kg.