User Manual Porty L
32
HENSEL-VISIT GmbH & Co. KG
Automatic power drop (APD)
When the flash output is reduced, the APD system (Automatic
Power Drop) depletes the stored energy internally. No flash is
triggered.
Triggering a test flash also drops the stored energy.
Test flash
The test flash is triggered by hand with the
TEST
key
9
. Holding
down the key results in the fastest possible sequence of flashes.
Audio
An audio signal can be added by pressing the
AUDIO
key
15
(control LED lights up) and acoustically confirms the following
functions:
•
Flash readiness after flashing (1x)
•
Automatic switch-off (2x)
•
Error message (1x long)
Flash readiness
Flash readiness after switching on is indicated by a LED
READY
10
. Flash readiness is also signalled by an audio signal if this
function is activated.