23
HENSEL-VISIT GmbH & Co. KG
AC Porty mains drawer removal
Â
Turn off the
Porty L
with the power switch
18
.
Â
Turn off the mains adapter with the power switch
28
.
The LED
POWER 30
goes out.
Â
Disconnect the mains cable from the power supply.
Â
Press the unlocking mechanism
29
on the mains drawer and
simultaneously pull the mains adapter out of the unit.
Switching the modeling light
In mains operation, flash heads with a 115 V modeling light
or a 230 V modeling light can be switched between full and
proportional operation.
Â
Press the
FULL/PROP.
key
31
The modeling light is set at maximum strength and the con-
trol lamp inside the key is lit.
Â
Press the
FULL/PROP.
key
31
again
The modeling light is now set proportional to the selected
output, the control lamp inside the key is off.
Flash head connection
ATTENTION!
Always switch off the generator before connecting a flash head.
Please note the general safety precautions listed in the
section„Generators, compact flash units and flash heads“ on
page 10 when handling flash heads.
Special flash heads are intended for the use with
Porty L
. The
flash head cable is connected via a round plug to the flash
head and to the generator.
Depending on the flash heads’ type of modeling light and whe-
ther the generator is operated with battery or mains adapter,
different functional properties and limitations apply. These are
listed in the following summary.