7-8. ROTATION CONTROL
4. Take a continuity reading across terminals. If meter
SWITCH (continued)
shows constant open or closed circuit each time the
button is pushed, the switch is defective.
5. Unscrew the back ring of switch and pull out switch
from the front of the unit.
6. Replace new switch, with a rubber washer on each
side of panel.
7. Replace wires on terminals.
8. Replace switch panel and restore power.
7-9. CAPACITOR REPLACE
-
MENT - BLOWER MOTOR
1. Remove electrical power supplied to unit.
Remove electrical power supplied to the unit by
unplugging the unit, or by turning off the wall
circuit breaker, or electrical shock could result.
2. Remove the side panel closest to the controls.
3. Disconnect wires from wire nuts.
4. Using a 1/2" socket, remove nut securing capacitor to
bracket and remove capacitor.
5. Install new capacitor in reverse order.
698
7-7