7-6. CONTACTOR
1. Remove electrical power to unit.
Checkout:
Remove electrical power supplied to the unit by unplugging the
unit, or by turning off the wall circuit breaker, or electrical shock
could result.
2. Remove the side panel closest to the controls.
3. Remove and label the wires from contactor.
4. Perform a check on the contactor as follows:
Test Points
Results
from 23 to 29 open circuit
from 24 to 28
open circuit
from 25 to 27
open circuit
from 22 to 26
ohm reading 415
Checkout - power supplied
The following checks are performed with the wall circuit breaker
closed and the main power switch in the ON position. Extreme
caution should be taken. Make connections before applying
power, take reading, and remove power before removing meter
leads, or electrical shock could result.
5.With power reapplied, let unit start heating up.