Henny Penny
SCR-6/8
2-5. LEVELING OF UNIT
For proper operation, the Rotisserie should be level from side to
side and front to back. This will ensure proper door operation.
2-6. ELECTRICAL
The Henny Penny rotisserie is available from the factory
REQUIREMENTS
wired 208 or 240 volt, 220-380 volt, 240-415 volt, 230-400
volt, 1 or 3 phase, 50/60 hertz service.
The cabinet must be adequately and safely grounded ac-
cording to local electrical codes to prevent the possibility
of electrical shock.
Model Product Volts Phase Amps Watts Wire
No. No.
SCR-8 02639 208
3
33.6 11,100
3+G
02638 208 1
50.5 11,100
2+G
02645 240
3
29.1 11,100
3+G
02638 240
1
46
11,100
2+G
SCR-6 02634 208
3
22.8 6800
3+G
02630 208 1
32.5 6800
2+G
02637 240
3
19.7 6800
3+G
02630 240
1
28.3 6800
2+G
2-4
500