Model OFG- 390
2-5. VENTILATION OF FRYER
The fryer should be located with provision for venting into
adequate exhaust hood or ventilation system. This is essential
to permit efficient removal of the flue gases and frying odors.
Special precaution must be taken in designing an exhaust
canopy to avoid interference with the operation of the fryer.
We recommend you consult a local ventilation or heating company
to help in designing an adequate system.
Ventilation must conform to local, state, and national codes.
Consult your local fire department or building authorities.
2-6. GAS SUPPLY
The gas fryer is factory available for either natural or propane gas.
Check the data plate on the right side panel of the cabinet to deter-
mine the proper gas supply requirements. The minimum supply for
natural gas is 7 inches water column, and 10 for propane.
Do not attempt to use any gas other than that specified
on the data plate. Incorrect gas supply could cause a
fire or explosion resulting in severe injuries and/or
property damage.
Please refer below for the recommended hookup of the fryer to
main gas line supply.
To avoid possible serious personal injury:
•
Installation must conform with local, state, and
national codes, and be in accordance with Cana-
dian Gas Authority Standard CSA B149-& 2,”
Installation Codes - Gas Burning Appliances” and
Australian Gas Authority Rule AG601-2000
Section AS5601.
•
The fryer and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 PSIG (3.45 KPA)
(34.47 mbar).
2-6
703
Содержание OFG-390
Страница 1: ...OPERATOR S MANUAL Henny Penny Open Fryer Model OFG 390 ...
Страница 2: ......
Страница 10: ......
Страница 13: ...Model OFG 390 OptionalRampUnloading 703 2 3 ...
Страница 14: ...Model OFG 390 2 4 908 ...
Страница 18: ...Model OFG 390 2 8 303 ...
Страница 22: ......
Страница 27: ...Model OFG 390 SMS Controls TEMPERATURE BUTTON DIGITAL DISPLAY PRODUCT BUTTONS Figure 3 2 303 3 5 ...