54
July 2003
This mode gathers and stores historic information on the fryer
and operator’s performance. Press
(PROG►) and (◄INFO) at
the same
time and “*INFO MODE*” shows on display. Press (PROG►)
or (◄INFO) to access the steps and press ▼ to view the statistics
within each step. Information Mode is intended for technical use,
but the operator can view the following information:
1.
E-LOG
- last 10 errors and time they occurred
2.
LAST LOAD
- information about the most recent Cook
Cycle, or the cycle presently in progress
3.
DAILY STATS
- information for the last 7 days
4.
REVIEW USAGE
- information accumulated since the last
time this data was manually reset
5.
INP A VHDSF PM.PM
- provides test of fryer inputs
6.
OUTP
- shows the state of heater and pressure
7.
OIL TMP
- temperature of shortening
8.
CPU TMP
- temperature of PC board
9.
ANALOG
- status of controller’s a-to-d converter
1. E-LOG
(error code log)
Press ▼ and “1A” (date & time) “*NOW*” show in display.
This is the present date and time.
Press ▼ and if a error was recorded, “1B” (date, time, and error
code information) shows in display. This is the latest error code
that the controls recorded.
Press ▼ and the next latest error code information can be seen.
Up to 10 error codes (1B to 1K) can be stored in the E-LOG
Section.
Press (PROG►) to continue to LAST LOAD.
Press and hold (PROG►)
to exit Information Mode at
any time, or after 2 minutes, controls automatically exit
back to normal operation.
3-19.
INFORMATION
MODE
Содержание OFE-391
Страница 2: ......
Страница 26: ...19 April 2003 14 1 2 3 4 5 6 7 8 9 13 11 12 10 COOK OFF PUMP ...