45
Oct. 2005
3-17.
SPECIAL
PROGRAM
MODE
The Special Program Mode is used to set more detailed
parameters listed below.
SP-1 · Degrees Fahrenheit or Celsius
SP-2 · Language: English, French, German, Spanish, and
Portuguese
SP-3 · System initialization
SP-4 · Audio volume
SP-5 · Audio tone
SP-6 · Type of shortening to be melted - liquid, solid
SP-7 · Idle Mode
SP-8 · Filter tracking
SP-9 · Product buttons
SP-10 · Clean-out minutes
SP-11 · Clean-out temperature
SP-12 · Nominal amps reading
SP-13 · Amps reading low limit (percentage)
SP-14 · Amps reading high limit (percentage)
SP-15 · Program code change
SP-16 · Usage code change
SP-17 · Change shortening - A-Cook Cycles
SP-18 · Change shortening - B-Hours
1.
Press and hold (PROG►) for 5 seconds until “L-2” and
“LEVEL 2”, followed by, “SP PROG” and “ENTER CODE”
show in the display.
2.
Enter code 1, 2, 3, and “SP- 1 “, “TEMP, UNITS” show in
the display.
To exit from the Special Program Mode at any time, press
and hold (PROG►) button for 2 seconds, or to roll back to
previous
setting, press (◄INFO).
DEGREES FAHRENHEIT OR CELSIUS (SP-1)
a.
Follow steps 1 and 2 above.
b.
The display flashes “SP- 1” and “TEMP, UNITS”,
along with “°F” or “°C”. Press ▼▲ buttons to toggle
from “°F” to “°C”, or vice versa.
If a bad code is entered, an alarm sounds and “BAD
CODE” shows on the display. Wait a few seconds, the
control reverts back to the Cook Mode, and repeat the
above steps.