background image

Model HCH-930/932

2-11.  HEATER

1. Disconnect the electrical supply to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.

2. Remove the cabinet top.

3. Remove the 2 screws securing the high limit to the heater, and pull

                                              Step 5

high limit from heater.

4. Remove the 2 wires attached to the heater terminals.

5. Remove the 2 screws securing the heater to the heater box cover,

and remove heater from unit.

6. Install new heater in reverse order.

7. Reconnect electrical supply to the cabinet.

2-12.  HIGH LIMIT

1. Disconnect the electrical supply to the cabinet.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.

2. Remove cabinet top.

3. Remove the 2 wires attached to the high limit.

4. Check for continuity across the 2 terminals of the high limit.  As

long as the temperature of the cabinet is below 210

o

 F (99

o

 C),

and the blower is operating properly, the high limit should be
closed.  If the high limit is defective, continue with the following
steps.

5. Remove the 2 screws securing the high limit to the heater, and pull

high limit from heater.

                                              Step 5

6. Install new high limit in reverse order.

7. Reconnect electrical supply to the cabinet.

203

                  2-7

Содержание HCH-930

Страница 1: ...TECHNICAL MANUAL Henny Penny Heated Holding Cabinet Model HCH 930 Model HCH 932...

Страница 2: ......

Страница 3: ...Clean Water Strainer 2 2 2 5 Replace Water Strainer 2 2 2 6 Cleaning Water Valve 2 3 2 7 Replacing Water Valve 2 4 2 8 Float Switch 2 5 2 9 Solid State Delay Timer 2 6 2 10 Blower 2 6 2 11 Heater 2 7...

Страница 4: ...ii 703...

Страница 5: ...especiallyimportantinformation CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CAUTION indicates a potential...

Страница 6: ...bad B Cabinetsteaming Toomuchhumidityinside Remove one or more baffles or product soggy cabinet from water pan WATER SYSTEM A Waterpannotfilling Water supply off or Check water supply line disconnect...

Страница 7: ...meter C Unit overheats Faulty thermostat Check thermostat Faulty blower Check blower and replace if bad POWER SECTION A With power switch Unit not connected to electrical Connect unit to electrical su...

Страница 8: ...Model HCH 930 932 THIS PAGE INTENTIONALLY LEFT BLANK 1 4 703...

Страница 9: ...llreadinfinity 2 3 DELIMINGWATER PAN Inspect the water pan and baffles every 10 days for lime buildup AND BAFFLES and clean when necessary Failure to keep the water pan and baffles free of lime buildu...

Страница 10: ...Make sure water pan issecureagainsttheceilingofthecabinet 7 Replace the top drawer 8 Reconnectelectricalsupplytocabinet 2 4 CLEAN WATER STRAINER 1 Shutoffwatersupply 2 Remove the hex cap at the botto...

Страница 11: ...the inlet side of the valve with a wrench and thenturnvalvecounterclockwiseuntilthevalveisfreefromthe fitting 9 Remove the 2 screws H from the coil retainer F 10 Remove the retainer and pull the coil...

Страница 12: ...onnect the electrical supply to the cabinet 2 7 REPLACINGWATER VALVE 1 Follow steps 1 through 8 of section 2 6 To avoid electrical shock or property damage move the power switch to OFFand disconnect m...

Страница 13: ...continuewiththestepsbelow 4 Cut the float switch wire that attaches to terminal 3 on the solid state relay 5 Removethe2screwssecuringthefloatswitchwellandpullthe well up and out of the heater box cove...

Страница 14: ...the back of the control panel with the 2 nutsremovedearlier 6 Replace the cabinet top 7 Reconnecttheelectricalsupply 2 10 BLOWER 1 Disconnecttheelectricalsupplytothecabinet To avoid electrical shock o...

Страница 15: ...upply to the cabinet 2 12 HIGH LIMIT 1 Disconnect the electrical supply to the cabinet To avoid electrical shock or property damage move the power switch to OFF and disconnect main circuit breaker or...

Страница 16: ...he2nutssecuringthebulbretainingclipsandremove thethermometerbulbfromtheclips 6 Removethenutsecuringthethermometertothemountingbrack et on the back of the thermometer body 7 Removethethermometerthrough...

Страница 17: ...he cabinet 5 Pull the blower box up to expose the thermometer and thermo stat bulbs Carefully lay the blower and blower box off to one side 6 Removethe2nutssecuringthebulbretainingclipsandremove theth...

Страница 18: ...rol panel 5 Remove the switch from the unit 6 Install the switch in reverse order Step 4 7 Replace cabinet top 8 Reconnect electrical supply to the cabinet 2 16 INDICATINGLIGHTS 1 Disconnect the elect...

Страница 19: ...fan Step 3 4 Remove the 4 nuts and screws securing the fan and remove fan fromthecabinet 5 Install new fan in reverse order 6 Strip ends of cut wires and connect them to the new fan wires Step 4 7 Re...

Страница 20: ...er the 2 drawer handle spacers over the screw holes so the handle screws pass through the spacers 2 19 DRAWER AND LINER Apply Loctite to screw threads when replacing drawer bearing kit BEARING REPLACE...

Страница 21: ...Model HCH 930 932 807 2 13 2 20 WIRING DIAGRAMS...

Страница 22: ...Model HCH 930 932 2 14 807 2 20 WIRING DIAGRAMS Continued...

Страница 23: ...Model HCH 930 932 807 2 15 2 20 WIRING DIAGRAMS Continued...

Страница 24: ...2 20 WIRING DIAGRAMS Continued 2 16 807...

Страница 25: ...2 20 WIRING DIAGRAMS Continued 807 2 17...

Отзывы: