3. Label and remove the wires from the
switch. Check across the terminals - top
and bottom terminals on the left side of
the switch, and top and bottom terminals
on the right side. In the ON position the
switch should show continuity. If switch
is defective, replace it and proceed with
procedures.
4. Replace with new switch in reverse
order and reconnect power to unit.
PROBE REPLACEMENT
In the event the temperature probe
becomes faulty, an error message E06
will be displayed. Turn the power switch
OFF and then back ON. If the error
message E06 is still displayed, the
temperature probe must be replaced.
Tools:
Phillips screwdriver, 3/8” (9 mm)
socket
1. Disconnect the electrical supply to the
cabinet.
WARNING: Place the power switch in
the OFF position and unplug the power
cord. Failure to do so could result in
electrical shock.
2. Remove the module housing.
3. Open the door to the unit and remove the
screws securing the probe to the module.
4. Remove the nuts securing the blower box
and pull the probe from under the box.
5. Unplug the probe from the PC board.
6. Install the new probe in reverse order and
restore power to the unit