background image

SERIAL #:

series 3 holding cabinets with CVap

®

 technology

HOV3-05UV
HOV3-10UV
HOV3-14UV

2345 Carton Drive | Louisville, Kentucky 40299  USA
winstonfoodservice.com | 800.234.5286 | +1.502.495.5400

class series 3

HOV

3

Содержание CVap HOV3 Series

Страница 1: ...SERIAL series 3 holding cabinets with CVap technology HOV3 05UV HOV3 10UV HOV3 14UV 2345 Carton Drive Louisville Kentucky 40299 USA winstonfoodservice com 800 234 5286 1 502 495 5400 class series 3 HOV3 ...

Страница 2: ...ecomes fluid by heating in higher levels than those which can be easily observed WARNING WARNING Burn Hazard When opening the door of the cooking compartment hot steam can come out DANGER DANGER Electrical Hazard If supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Warnings MISUSE AND OTHER Warranty Terms and ...

Страница 3: ... to your location auto water fill Automatic water fill is available as an optional feature Auto water fill systems must be hooked up to a potable water supply line The maximum incoming water temperature may not exceed 140 F 60 C and the incoming water pressure must be between 20 and 150 psi 137 9 kPa to 1034 kPa Equipment with auto water fill systems MUST NOT BE ALLOWED TO RUN DRY Heat damage to t...

Страница 4: ...0 winstonfoodservice com equipment type class series 3 4 Vapor water Temperature controls Air Temperature controls Icon Indicators Power Button Enter Button Menu and Temperature display Back Button Display New Winston CVap Control Navigation ...

Страница 5: ...hips fries etc Off to 130 F Off to 50 C 180 to 200 F 82 to 93 C Food Holding Reference Chart 1 Ensure that the evaporator pan has water in it before turning the unit on 2 Press the power button to turn the unit on 3 Press the up or down button to set the water temperature 4 Press the up or down button to set the air temperature 5 Place product in unit after heated is displayed Is illuminated when ...

Страница 6: ...the display temperature readout to show air or evaporator temperature o Temperature Scale Adjust between Fahrenheit or Celsius o Fill System Adjust setting for Water Level Sensor disabled probe or float and Water Valve disabled or enabled o Tuning Calibrates vapor temperature for the size and model of the unit for maximum precision To access the main menu Press and hold the menu button for 3 secon...

Страница 7: ... any chemical used to clean equipment is free of sodium and other ingredients that could be corrosive to metal 1 Disconnect power supply Allow equipment to cool 2 Place empty pan under drain valve open drain valve and allow evaporator to drain 3 Remove and clean rack supports using a food grade germicidal agent Rinse and allow to dry 4 Remove evaporator cover and clean then allow cover to dry Proc...

Страница 8: ...84 2134mm minimum power cord and plug The input average of current did not exceed the allowable amperage for the circuit listed CAPACITY EXTERIOR DIMENSIONS ELECTRICAL MODEL SHEET PAN 18 x 26 HALF SHEET PAN 18 x 13 HOTEL PAN 12 x 20 x 2 5 HEIGHT IN MM DEPTH IN MM WIDTH IN MM VOLTS PHASE WATTS AMPS NEMA INT L SHIP WEIGHT LBS KG HOV3 05UV 5 10 10 39 22 996 34 23 869 27 70 704 120 1 2292 19 1 5 20P C...

Страница 9: ...lass series 3 2345 Carton Drive Louisville KY 40299 USA winstonfoodservice com 800 234 5286 1 502 495 5400 Specifications subject to change without notice Copyright 2020 doc20200110wlp1rev07 wp 01 15 20 ...