![Henny Penny EVOLUTION ELITE EEE-181 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/henny-penny/evolution-elite-eee-181/evolution-elite-eee-181_technical-manual_2124328007.webp)
Model EEE-182
1-3
Problem
Cause
Correction
POWER switch ON
but fryer completely
inoperative
• Open circuit
• Plug fryer in
• Check breaker or fuse at supply
box
• (Non-US/some Int’l. locations
only)
Breakers in fryer tripped-open
left door and reset breaker on
fryer; See below
Oil will not heat but lights
are on
• All power cords not
plugged-in
• Unit has 2 power cords; make
sure both are plugged-in
Control error code “E-10” • Open high limit circuit
• Let unit cool down (15-20
minutes), reset the high limit
switch on the inside of the
LH door; if high limit does
not reset, high limit must be
replaced.
Vat is under-filled
• JIB is low or empty
• JIB oil line is clogged or
collapsed
• Filter pan needs cleaned
• Fill the JIB
• Check JIB line
• Clean filter pan and change
paper or pad
July 2016
Содержание EVOLUTION ELITE EEE-181
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 24: ...Model EEE 182 4 4...
Страница 71: ...Model EEE 182 6 29 July 2016...
Страница 72: ...Model EEE 182 6 30 July 2016...
Страница 73: ...Model EEE 182 6 31 July 2016...
Страница 74: ...Model EEE 182 6 32 July 2016...
Страница 75: ...Model EEE 182 6 33 July 2016...
Страница 76: ...Model EEE 182 6 34 July 2016...
Страница 77: ...Model EEE 182 6 35 July 2016...
Страница 78: ...Model EEE 182 6 36 July 2016...
Страница 79: ...Model EEE 182 6 37 July 2016...
Страница 80: ...Model EEE 182 6 38 July 2016...
Страница 81: ...Model EEE 182 6 39 July 2016...
Страница 82: ...Model EEE 182 6 40 July 2016...
Страница 83: ...Model EEE 182 6 41 July 2016...
Страница 84: ...Model EEE 182 6 42 July 2016...
Страница 90: ...Model EEE 182 7 6 17kw Full Heating Elelemnt Assy July 2016...
Страница 92: ...Model EEE 182 7 8 High Limit Control Modules Reset Switches and Wiring July 2016...
Страница 117: ......
Страница 118: ......