Model EEE-182
6-17
6-13. FILTER PUMP & MOTOR
The 2 most common causes for a fryer not to pump oil are that
the pump is clogged, or the thermal overload switch has been
tripped on the motor. The pump and motor is located on the
rear of the fryer.
To remove debris from pump:
1. Loosen the four Allen head screws on the end of pump
and remove the cover. (Removing the bottom rear panel
may help in accessing the set screws.)
2. The inside is now exposed leaving a rotor and five teflon
rollers. Clean the rotor and rollers.
3. To reassemble, place rotor on drive shaft, and place roller
into rotor.
A small amount of grease might be needed to hold the
bottom roller into place until cover plate is put on. Make
sure O-ring is in proper position on plate.
There is an indicator on the side of the two halves of the
pump, this mark must be together
To reset the thermal overload switch:
1. Locate the pump and motor in the rear of the fryer and if
the motor is hot, allow it to cool for about 5 minutes.
2. Since it takes some effort to reset the switch, use a tool,
such as a Phillip’s-head screwdriver, to press against the
reset button until a “click” is heard.
July 2016
Содержание EVOLUTION ELITE EEE-181
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 24: ...Model EEE 182 4 4...
Страница 71: ...Model EEE 182 6 29 July 2016...
Страница 72: ...Model EEE 182 6 30 July 2016...
Страница 73: ...Model EEE 182 6 31 July 2016...
Страница 74: ...Model EEE 182 6 32 July 2016...
Страница 75: ...Model EEE 182 6 33 July 2016...
Страница 76: ...Model EEE 182 6 34 July 2016...
Страница 77: ...Model EEE 182 6 35 July 2016...
Страница 78: ...Model EEE 182 6 36 July 2016...
Страница 79: ...Model EEE 182 6 37 July 2016...
Страница 80: ...Model EEE 182 6 38 July 2016...
Страница 81: ...Model EEE 182 6 39 July 2016...
Страница 82: ...Model EEE 182 6 40 July 2016...
Страница 83: ...Model EEE 182 6 41 July 2016...
Страница 84: ...Model EEE 182 6 42 July 2016...
Страница 90: ...Model EEE 182 7 6 17kw Full Heating Elelemnt Assy July 2016...
Страница 92: ...Model EEE 182 7 8 High Limit Control Modules Reset Switches and Wiring July 2016...
Страница 117: ......
Страница 118: ......