Error messages
54
Service instructions
Perform DynaSteam test again and check water quantity with
measurement container.
The water quantity corresponds to the set quantity (±10%).
Replace pressure switch.
The water quantity does not correspond to the set quantity
(±10%). Ensure that the supply pipe is not clogged. Replace
steaming unit.
Perform the DynaSteam test in the Service menu.
No water runs through the water supply pipe into the cooking
chamber.
Check water supply pipe for calcification.
Ensure that the hose between the steaming unit and supply pipe
is not clogged.
Replace steaming unit.
10015160-0ASAE-A
Содержание 6.10
Страница 39: ...Electronics 39 Service instructions 8 2 Control board 8 2 1 Layout 10015160 0ASAE A ...
Страница 56: ...Error messages 56 Service instructions 10015160 0ASAE A ...
Страница 57: ......