Service menu - appliance test
11
Service instructions
5.3 Status overview
Status 1
Heating circuit
PWM: heat requirement in %.
POS: power optimization system (option).
Temperature sensors B1, B3, B6, B7 are not present.
Status 2
Climate control system, fan
B14: Pressure switch on the DynaSteam unit
PWM: heat requirement in %.
Temperature sensor B3 is not present.
No indicator of fan speed for unit size 6.23.
Status 3
WaveClean (option)
K04: Magnetic valve for water vapor elimination & siphon filling
B15: Reed contact switch
B14: Pressure switch on the DynaSteam unit
Temperature sensor B3 is not present.
10015160-0ASAE-A