Error messages
50
Service instructions
9.6 Overtemperature control (TMP_ID2)
Description The temperature sensor on the control board is measuring a
temperature of >70°C. The unit is no longer operational until it cools
down.
Troubleshooting
Check air intake area of fan.
Clean dirty air intake area.
Check that cooling fan is functioning properly. To do so, use the
relay test in the Service menu to switch on the cooling fan.
The cooling fan does not start. Measure the voltage at the fan.
Voltage present = Cooling fan defective. Voltage not present =
Relay on the control board defective. Replace control board.
The cooling fan starts. Check surroundings and ambient
temperature. See also installation instructions.
9.7 Risk of frost (TMP_ID72)
Description The unit is not ready for use. The temperature sensor on the control
board is measuring a temperature of <0°C.
Troubleshooting
Increase the room temperature and switch on unit again.
Change location of the unit.