![Henny Penny 6.10 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/henny-penny/6-10/6-10_service-instructions-manual_2124406040.webp)
Electronics
40
Service instructions
8.2.2 Configuration
Connector X1
No.
Description
Conductor
number
1
Input 10.7 V AC for lighting
2
3/4
Power supply I/O board 18V AC
Connector X2, X3, X4 Not assigned
Connector X5 CAN bus line to motor M10 (only for unit size 6.1)
Connector X6 Not assigned
Connector X7 MMI communication
Connector X8 Digital key contains device-specific information.
Connector X9 (24V DC)
No.
Description
Conductor
number
1/2
Supply for control panel (MMI)
Connector X10 (230V AC)
No.
Description
Conductor
number
1
Supply voltage for relay
2
Output K1, main contactor Q1
3
-
4/5
N
Connector X11 (230V AC)
optional
No.
Description
Conductor
number
1
Output K1, POS A
2
Output K2, POS B
3
Input 230V, POS C
4
-
5
N
Connector X12 (230V AC)
No.
Description
Conductor
number
1
Output K17, WaveClean pump G16
2
Output K3, magnetic valve K23
3
Output K4, magnetic valve K12
4
Output K5, siphon pump G24
5
Output K6, backup relay
6
-
7
N
Connector X13 (potential-
free)
Only assigned for unit size 6.23.
10015160-0ASAE-A