20 • Service Manual — COATS Model IBS 2000
Direct Drive
Keypad Problems.
Keypad Problems.
Yes
Keypad Problems.
No
Yes
A/D ARM PROBLEMS
Perfor m pre-
diagnostic check.
Retur n the ar m to
HOME. Is the W
now flashing?
No
Yes
Is the ar m in HOME
position?
Yes
No
Are the
potentiometer
readings within
tolerance?
S e e K E Y PA D f l ow
char t.
C h e ck
Potentiometer
adjustments. See
A R M
C A L I B R AT I O N .
Troubleshooting
complete.
Retur n to
operation.
Adjust the
potentiometers. Are
the readings stable?
Check Cable
connections at CPU
board and Ar m.
Replace the cable.
Troubleshooting
comptete. Calibrate
the arm. Calibrate the
balancer.
Yes
Use VOM to check supply
voltage on the A & D
potentiometers. Between
pins 1&3 for D, and 4&6
for A. Is voltage stable?
No
Yes
No
Use VOM to check
voltages on the
potentiometers
between 2&3 for D
and 5&6 for A. Are the
readings stable?
C h e ck
connections or
replace the
potentiometers.
Troubleshooting
complete.
Calibrate the Ar m,
Calibrate the
balancer.
Yes
Use VOM to check
voltage on P7 of
CPU board;
between pins 1&2
and 4&5. Are the
readings stable?
Yes
No
R e p l a c e C P U
board.
A & D Arm
Problems
Содержание Coats IBS 2000
Страница 2: ...ii Service Manual COATS Model IBS 2000 Direct Drive...
Страница 26: ...22 Service Manual COATS Model IBS 2000 Direct Drive Motor Controller Diagram...
Страница 36: ...32 Service Manual COATS Model IBS 2000 Direct Drive IBS 2000 Wiring Diagrams...
Страница 37: ...Service Manual COATS Model IBS 2000 33 Direct Drive...
Страница 38: ...34 Service Manual COATS Model IBS 2000 Direct Drive...
Страница 39: ...Service Manual COATS Model IBS 2000 35 Direct Drive...
Страница 40: ...9112388 01 12 00 Copyright 1998 Hennessy Industries and COATS All Rights Reserved Printed in USA...