Service Manual — COATS Model IBS 2000 • 15
Keypad Problems.
Perfor m keypad test
f r o m m a i n m e n u
Diagnostic. The
b a l a n c e r mu s t b e
displaying infor mation
to proceed. Does this
indicate a problem?
R e p l a c e Key p a d
N o
Ye s
N o
Ye s
Check keypad
connections.
Does this correct the
problemt?
Wa s key p a d l o cke d
up at power up?
Cycle the power
again. Does this
correct the problem?
Ye s
N o
Ye s
Troubleshooting
c o m p l e t e.
Keypad Problems.
Perfor m keypad test
f r o m m a i n m e n u
Diagnostic. The
b a l a n c e r mu s t b e
displaying infor mation
to proceed. Does this
indicate a problem?
R e p l a c e Key p a d
N o
Ye s
N o
Ye s
Check keypad
connections.
Does this correct the
problemt?
Wa s key p a d l o cke d
up at power up?
Cycle the power
again. Does this
correct the problem?
Ye s
N o
Ye s
Troubleshooting
c o m p l e t e.
Keypad Problems.
Perfor m keypad test
f r o m m a i n m e n u
Diagnostic. The
b a l a n c e r mu s t b e
displaying infor mation
to proceed. Does this
indicate a problem?
R e p l a c e Key p a d
N o
Ye s
N o
Ye s
Check keypad
connections.
Does this correct the
problemt?
Wa s key p a d l o cke d
up at power up?
Cycle the power
again. Does this
correct the problem?
Ye s
N o
Ye s
Troubleshooting
c o m p l e t e.
Keypad Problems.
Pe r fo r m p r e -
diagnostic check
(balancer must be
displaying
m e r c h a n d i s i n g
m e s s a g e t o p r o c e e d ) .
Perfor m keypad test
f r o m m a i n m e n u
Diagnostic. The
b a l a n c e r mu s t b e
displaying infor mation
to proceed. Does this
indicate a problem?
R e p l a c e Key p a d
N o
Ye s
N o
Ye s
Check keypad
connections.
Does this correct the
problemt?
Wa s key p a d l o cke d
up at power up?
Cycle the power
again. Does this
correct the problem?
Ye s
N o
Ye s
Troubleshooting
c o m p l e t e.
N OT E : When a key is shor ted or locked down at power up,
1. the LCD may be lighted but blank.
2. the "Press Any Key to Continue" message may be
displayed.
3. the LCD may be in another mode such as:
ADJUST LCD CONTRAST
BALANCER DISPLAY DIAGNOSTICS
Direct Drive
Keypad Problems
Содержание Coats IBS 2000
Страница 2: ...ii Service Manual COATS Model IBS 2000 Direct Drive...
Страница 26: ...22 Service Manual COATS Model IBS 2000 Direct Drive Motor Controller Diagram...
Страница 36: ...32 Service Manual COATS Model IBS 2000 Direct Drive IBS 2000 Wiring Diagrams...
Страница 37: ...Service Manual COATS Model IBS 2000 33 Direct Drive...
Страница 38: ...34 Service Manual COATS Model IBS 2000 Direct Drive...
Страница 39: ...Service Manual COATS Model IBS 2000 35 Direct Drive...
Страница 40: ...9112388 01 12 00 Copyright 1998 Hennessy Industries and COATS All Rights Reserved Printed in USA...