10 • Service Manual — COATS Model IBS 2000
Direct Drive
#8 -
Internal Error Code: Displayed at power up when
the data on the EE PROM is different than when the
unit was turned off. Recalibrate the Balancer and the
A/D Arm. If this message continues replace the CPU
board.
#9 -
An Invalid Model Selection Has Been Made:
Displayed when the dipswitches on the CPU board are
not set correctly, or the connections are bad. Check the
dipswitch settings (they should all be in the ON posi-
tion) and reset if necessary. If this does not correct the
problem, replace the CPU.
#10 -
The Automatic Arm Is Not Present: Displayed
during Arm Calibration when the CPU cannot detect
the arm. Check the arm cable/PCB connections, or the
CPU connector.
#11 -
The A & D Pots Are Not Properly Adjusted:
Displayed during Arm Calibration if the pots were not
properly adjusted. Press CONTINUE to readjust, or
CANCEL to quit.
#12 -
The A Pot Is Not Properly Adjusted: Displayed
when the A pot is not reading correctly. Same as #11
except for the A pot only. Press CONTINUE to readjust,
or CANCEL to quit.
#13 -
The D Pot Is Not Properly Adjusted: Displayed
when the D pot is not reading correctly, Same as #12
except for the D pot only. Press CONTINUE to readjust,
or CANCEL to quit.
#14 -
The Hood Was Raised During The Measurement
Cycle: Displayed if the hood is raised during the cycle.
Lower the hood and respin.
#15 -
The Motor Ran In Reverse At Start Up: Displayed
when the motor accelerated in reverse at start up.
Check phase, AC power, or MC (motor controller).
#16 -
The Arm Was Not In The Correct Position:
Displayed during Arm Calibration if you get out of
sequence. Press CONTINUE to repeat or CANCEL to
quit.
#17 -
No Encoder Pulses At Start Up: Displayed when
no encoder is detected at start up. Check cable, AC
power and motor. Refer to “Wheel Does Not Spin”
flow chart.
#18 -
No Phase A Encoder Pulse At Start Up: Same as
#17, but for Phase A only. See “Wheel Does Not Spin”
flow chart.
#19 -
No Phase B Encoder Pulse At Start Up: Same as
#17, but for Phase B only. See “Wheel Does Not Spin”
flow chart.
#20 -
The Hub Nut Is Loose Or There Is No Wheel
Mounted: Displayed when the hub nut is not tight and
the wheel slips, or the faceplate assembly is not tight
on the motor shaft. Recheck the hubnut or refer to
“Faceplate Assembly Installation” on pg. 5. Press
CONTINUE to proceed.
#21 -
The Wheel Is Turning Too Fast For A
Measurement To Be Made: The motor speed is greater
than the maximum operating speed.
#22 -
The Wheel Turned In Reverse After The Motor
Was Started: Displayed when something interferes
with the rotation of the wheel after start up (someone
holding the wheel). Press CONTINUE to proceed.
Check cables or SSR. Press CONTINUE to proceed.
#23 -
The Wheel Turned Too Slow: Displayed under
similar conditions as #22 . Check cables or SSR. Press
CONTINUE to proceed.
#24 -
The Motor Accelerated Forward During
Breaking: Displayed when there is a phase problem
with the SSR, very rare. Check loose shutter wheel or
loose faceplate. Check encoder cable, AC power,
motor, and SSR. Press CONTINUE to proceed.
#25 -
The Time Required To Stop The Motor Was Too
Long: Displayed if a phase is lost on the SSR. Check AC
power, cables, and SSR. Press CONTINUE to proceed.
Содержание Coats IBS 2000
Страница 2: ...ii Service Manual COATS Model IBS 2000 Direct Drive...
Страница 26: ...22 Service Manual COATS Model IBS 2000 Direct Drive Motor Controller Diagram...
Страница 36: ...32 Service Manual COATS Model IBS 2000 Direct Drive IBS 2000 Wiring Diagrams...
Страница 37: ...Service Manual COATS Model IBS 2000 33 Direct Drive...
Страница 38: ...34 Service Manual COATS Model IBS 2000 Direct Drive...
Страница 39: ...Service Manual COATS Model IBS 2000 35 Direct Drive...
Страница 40: ...9112388 01 12 00 Copyright 1998 Hennessy Industries and COATS All Rights Reserved Printed in USA...