Henley Stoves BIO 80 Скачать руководство пользователя страница 28

BIO Pellet Stoves

 

27

 

 

 

 

 

GUARANTEE 

Fair srl guarantees the quality of manufacture and of the materials used.  
The Guarantee is valid for a period of 2 years and runs from the date of first start-up performed within 20 days of 
the purchase by personnel certified by Fair authorised §Service Centre, as long as 24 months have not elapsed 
since the purchase date. In this case, the Guarantee will have to be recognised by the seller.  
The first start-up is flat rate at the user's expense.  
The certificate must be marked by the stamp of the staff that carried out the installation.  
During that period, the dealer undertakes to repair and/or replace free of charge those parts which in its own 
exclusive judgement prove to be defective.  
Such repairs shall not alter the date of expiry of the Guarantee.  

 

The Guarantee is valid only on the following conditions:  
1 - The appliance must be installed with standard fume piping for pellet stoves with maximum length of 3/5 

metres including elbows (for different application, contact customer service).  

2 - Do not install on your own.  
3 - Extraordinary maintenance must be carried out once a year by Fair Authorised Service Centres. 4 
– All the procedures in the "Maintenance" chapter must be observed carefully.  

 

The Guarantee does not cover:  
1 - Damage caused by incorrect installation of the equipment or by unsuitability of the system.  
2 - Faults resulting from negligence, lack of care, incompetent use, or repairs carried out by non-authorised third 

parties.  

3 - Damage caused by transportation.  
4 - Work to modify parameters or chimney flue.  
5 - Parts normally subject to wear or which last less than the aforementioned Guarantee period. For example:  

the glow plug, gaskets, the brazier, the firebox lining, ceramic glass, painted parts of ceramic etc.  

 

The guarantee is valid for 24 months from the date of first start-up as indicated on this certificate, which should 
be completed correctly and accompanied by the receipt of purchase as proof. The apparatus is not guaranteed in 
any way for non-domestic use.   

 

The same applies in the event that the staff of the Technical Service Centre or of Fair srl discover while doing 
repairs that the date of installation/first start-up is not the true one (which can be detected from identifying details 
and other elements in the equipment).  
The present certificate must be presented to the staff of the Authorised Customer Service Centre, together with a 
document of proof of purchase (invoice or docket), every time the client asks  for an intervention during the 
guarantee period.  
Fair srl will not be liable for loss or damage caused to persons or things resulting from breakdown, forced 
suspension of use of the equipment or improper use.  

 

The Guarantee is valid only on the following conditions:  
1 - The equipment must be installed by qualified personnel.  
2 - The instalment must be done in accordance with the Laws in force in the territory and according to the 

directions given in the instruction manual.  

3 - Any repairs must be carried out only by staff of Authorised Service Centres.  
4 - The Guarantee certificate must be completed in all its parts in a clear and readable manner. 5 
- If routine maintenance is performed regularly.  
6 - If the appliance is earthed.  

 

Fair srl grants no other Guarantees apart from the above.  
In case of any dispute, the Court of Vicenza shall have Jurisdiction. 
IMPORTANT: the first start-up is t the client's expenses.  

 

European Guarantee: 24 months on spare parts and labour.  

 

Registering your new stove 

Henley Stoves does not accept warranty submissions through post/email 

Please register your warranty at 

https://henleystoves.com/henley-warranty/

 

 

The appliance must be installed by a HETAS / METAC approved fitter in accordance with Building 

Regulations in order for the warranty to be valid. 

 

If upon opening the stove, it is found to be damaged in any way, do not attempt to install the stove. 

Return to retailer where it was purchased from. 

Содержание BIO 80

Страница 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Страница 2: ...allow a very low noise level Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The...

Страница 3: ...failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is excluded from any contractual or extra contractual liability for...

Страница 4: ...heck the size of your room is not larger than what is recommended for maximum sizes a 7 7kW will sufficiently heat We recommend referring to an online stove output to room size calculator to help you...

Страница 5: ...there is smoke will cause further smoke to build and not be extracted What setting should I use when starting my pellet stove Upon each use It is highly recommended starting with Level 1 with a tempe...

Страница 6: ...emoved when an appliance is replaced unless proven to be recently installed and in good condition The installation of manual draft adjustment devices on forced draft appliances is not permitted The mi...

Страница 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Страница 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Страница 9: ...metically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid thi...

Страница 10: ...m thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you cannot use pipes made of asbestos cement or flexible metal The pipes must be sealed with high...

Страница 11: ...e only combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend using pellets of superior quality as that has major influ...

Страница 12: ...methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is If...

Страница 13: ...or 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expected l...

Страница 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Страница 15: ...play B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed D...

Страница 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h 2...

Страница 17: ...s in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light wi...

Страница 18: ...the stove in summer mode the display will show Ven flanked by the value of the power while in winter mode will display Start Optional remote control With the remote control it is possible to adjust t...

Страница 19: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Страница 20: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Страница 21: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Страница 22: ...3 Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inp...

Страница 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Страница 24: ...BIO Pellet Stoves 23 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Страница 25: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Страница 26: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Страница 27: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Страница 28: ...tificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Страница 29: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Страница 30: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Страница 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Страница 32: ...BIO Pellet Stoves 31...

Страница 33: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...