![Henley Stoves BIO 80 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/henley-stoves/bio-80/bio-80_maintenance-and-user-manual_2124030010.webp)
BIO Pellet Stoves
9
Pic. 7
The air intake must
be at a distance of:
1.5 m
Below
Doors, windows, fume exhaust, air
spaces etc.
1.5 m
Level with
Doors, windows, fume exhaust, air
spaces etc.
0.3 m
Above
Doors, windows, fume exhaust, air
spaces etc.
1.5 m
Far away
Smoke outlet
Connection to the chimney flue
Pic. 8
A pellets stove works with a fumes draft forced by a ventilator; therefore, you must be sure that all piping
is properly made as explained in this chapter by specialised staff. The pipes fitting between the stove
and the chimney flue must be short to support the draft and avoid the formation of condensate inside
the pipes. The diameter of the fumes pipe must be equal to or bigger than the diameter of the waste
fumes pipe (diameter 80mm).
For the fumes pipe fitting you should use pipe made of plate for stove-setting, type B22 with silicone
strips, pipes of painted aluminates steel (minimum thickness 1,5mm) or made of stainless steel A316
or porcelain zed (minimum thickness 0,5mm) with a diameter of 80 mm or 100mm depending on the
type of plant (see picture 2 pag.6), you cannot use pipes made of asbestos cement or flexible metal.
The pipes must be sealed with high temperature silicone (min. 250°) and fixed together with a self-
threading screw with diameter 3.9. You must always use a T pipe fitting (see picture 8) with inspection
plug, which allows an easy periodic cleaning of the pipes without having to disassemble them.
Make sure that after the cleaning the inspection plugs are closed hermetically with good strip. For
changes of direction, you can only use 3 T pipefitting and the fumes pipe length must not exceed 2
meters of horizontal projection with a minimum gradient of 5% (see picture 2 pag.6). You cannot link
more than one appliance to the same fumes pipe, you cannot direct the waste fumes coming from above
hoods into the same fumes pipe, you cannot discharge the combustion products through the wall
directly to the outside or to close spaces in open air. You cannot connect any other type of appliances
(wood stoves, hoods, boilers etc.). You cannot fit butterfly valves or anything that can block the fumes
passage anyway.