Henley Stoves BIO 80 Скачать руководство пользователя страница 10

BIO Pellet Stoves

 

9

 

 

 

 

 

 

 

Pic. 7  

 
 

The air intake must 

be at a distance of:  

 

 

1.5 m  

Below  

Doors, windows, fume exhaust, air 

spaces etc.  

1.5 m  

Level with  

Doors, windows, fume exhaust, air  

spaces etc.  

0.3 m  

Above  

Doors, windows, fume exhaust, air  

spaces etc.  

1.5 m  

Far away  

Smoke outlet  

 

 

 

Connection to the chimney flue  

Pic. 8  

 

A pellets stove works with a fumes draft forced by a ventilator; therefore, you must be sure that all piping 
is properly made as explained in this chapter by specialised staff. The pipes fitting between the stove 
and the chimney flue must be short to support the draft and avoid the formation of condensate inside 
the pipes. The diameter of the fumes pipe must be equal to or bigger than the diameter of the waste 
fumes pipe (diameter 80mm).  
For the fumes pipe fitting you should use pipe made of plate for stove-setting, type B22 with silicone 
strips, pipes of painted aluminates steel (minimum thickness 1,5mm) or made of stainless steel A316 
or porcelain zed (minimum thickness 0,5mm) with a diameter of 80 mm or 100mm depending on the 
type of plant (see picture 2 pag.6), you cannot use pipes made of asbestos cement or flexible metal. 
The pipes must be sealed with high temperature silicone (min. 250°) and fixed together with a self- 
threading screw with diameter 3.9. You must always use a T pipe fitting (see picture 8) with inspection 
plug, which allows an easy periodic cleaning of the pipes without having to disassemble them.  

 

Make sure that after the cleaning the inspection plugs are closed hermetically with good strip. For 
changes of direction,  you can only use 3 T pipefitting and the fumes pipe length must not exceed 2 
meters of horizontal projection with a minimum gradient of 5% (see picture 2 pag.6). You cannot link 
more than one appliance to the same fumes pipe, you cannot direct the waste fumes coming from above 
hoods into the same fumes pipe, you cannot  discharge the combustion products through the wall 
directly to the outside or to close spaces in open air. You cannot connect any other type of appliances 
(wood stoves, hoods, boilers etc.). You cannot fit butterfly valves or anything that can block the fumes 
passage anyway.

  

Содержание BIO 80

Страница 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Страница 2: ...allow a very low noise level Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The...

Страница 3: ...failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is excluded from any contractual or extra contractual liability for...

Страница 4: ...heck the size of your room is not larger than what is recommended for maximum sizes a 7 7kW will sufficiently heat We recommend referring to an online stove output to room size calculator to help you...

Страница 5: ...there is smoke will cause further smoke to build and not be extracted What setting should I use when starting my pellet stove Upon each use It is highly recommended starting with Level 1 with a tempe...

Страница 6: ...emoved when an appliance is replaced unless proven to be recently installed and in good condition The installation of manual draft adjustment devices on forced draft appliances is not permitted The mi...

Страница 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Страница 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Страница 9: ...metically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid thi...

Страница 10: ...m thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you cannot use pipes made of asbestos cement or flexible metal The pipes must be sealed with high...

Страница 11: ...e only combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend using pellets of superior quality as that has major influ...

Страница 12: ...methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is If...

Страница 13: ...or 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expected l...

Страница 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Страница 15: ...play B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed D...

Страница 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h 2...

Страница 17: ...s in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light wi...

Страница 18: ...the stove in summer mode the display will show Ven flanked by the value of the power while in winter mode will display Start Optional remote control With the remote control it is possible to adjust t...

Страница 19: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Страница 20: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Страница 21: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Страница 22: ...3 Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inp...

Страница 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Страница 24: ...BIO Pellet Stoves 23 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Страница 25: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Страница 26: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Страница 27: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Страница 28: ...tificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Страница 29: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Страница 30: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Страница 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Страница 32: ...BIO Pellet Stoves 31...

Страница 33: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...

Отзывы: