BIO Pellet Stoves
26
The stove switches off.
Alarm displayed: “Al 8 alar
al 8 Failure Depress”
•
The door isn’t closed
•
The waste outlet is obstructed
•
Fumes extractor is damaged
•
Rubber connection is obstructed
•
Pressure switch is faulty
•
Electronic card is faulty
•
Excessive chimney length
•
Bad weather conditions
•
Closed the door properly and check
the door strips are in good conditions
otherwise replace them.
•
The fumes waste chimney is partially
or totally obstructed (call an expert
stove fitter to check the chimney from
the stove outlet to the chimney pot).
Have it cleaned immediately.
•
Pellets can burn thanks to the
chimney flue depression without the
aspirator. Have it replaced
immediately as it can be bad for your
health. Call a specialised technician.
•
Take the silicone pipe off and with the
help of a pointed tool clean the
bodying hole. Replace the pipe if
necessary.
•
Replace the pressure switch. Call a
specialised technician.
•
Replace the card. Call a specialised
technician.
•
Call an expert stove setter to verify if
the chimney is according to the law
(see paragraph 2).
•
When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again.
The stove at work "SerV"
display
•
Cleaning the stove
•
The stove requires extraordinary
cleaning. Call specialized technician.