14
5 Dispensing
5.2 Refilling the Product Reservoir
Error message „ --- Refill ---“
(see Chapter 7):
The error message display blinks.
● Prepare product for refilling.
Error
message „ --- Empty ---“ with
beeping:
The error message display blinks. The
dispensing sequence is interrupted and no
further dispensing sequence can be
started.
● Press the button to stop the beeping.
The reservoir is automatically depressurized following the empty message.
● Refill the reservoir according to its instruction manual and reconnect.
Error message „
PRESS ENTER>Tank
Inactive<
“ (product reservoir (
Tank
) not
pressurized):
● Press button once (PRESS ENTER).
The reservoir is pressurized.
The error message „
Press. 0.83 NOK
“ (
Press.
= Dispensing pressure) blinks in the
digital display with beeping. The value
0.83
[bar/psi] is only an example for the indication
of the dispensing pressure (see Chapter 7).
The error message „Press 0.83 NOK“ with beeping
disappears by itself
when the
dispensing pressure in the product reservoir does not deviate more than 10 % from the
stored comparison value of the automatic pressure control.
After the error message „ Press. 0.83 NOK “ with beeping has disappeared:
● Continue dispensing with the stored values for dispensing time and pressure.
Содержание Loctite 135550
Страница 1: ...22121 97102 135550 ...
Страница 2: ...2 ...
Страница 18: ...18 8 Pin Assignment 8 2 XS1 External Start 8 3 XS1 Start via Promixity Switch ...
Страница 20: ...20 9 Declaration of Conformity ...
Страница 21: ...22121 ...
Страница 37: ...37 8 Steckerbelegung 8 2 XS1 Externer Start 8 3 XS1 Start über Näherungsschalter ...
Страница 39: ...39 9 CE Konformitätserklärung ...