5 Dispensing
5.1.2 Adjusting the Dispensed Quantity
5.1.2.1 Time Controlled Mode
This mode of operation is used for spot shaped wetting or drop dispensing.
● With buttons or set the dispensing
time to 0.50 s (factory setting). The
indication of the dispensing time in the
digital display begins blinking.
● With the pressure regulator
8
set the
dispensing pressure to 0.50 bar (approx.
7 psi). An error message „
Press. 0.83
NOK
“ with beeping is possible. The
value
0.83
[bar/psi] is only an example
for the indicated dispensing pressure
(see Chapter 7).
● Press button to store the dispensing
pressure setting as the comparison
value for automatic pressure monitoring.
The error message with beeping is
eliminated.
● Press the Footswitch
15
to check the
dispensed quantity.
If the dispensed quantity is too small:
● Increase the dispensing pressure and store. Check the dispensed quantity again.
Repeat this sequence until the desired dispensed quantity is roughly achieved.
When the desired dispensed quantity is roughly achieved:
● Set the exact dispensed quantity by changing the dispensing time with button or .
● Press the Footswitch
15
to check the dispensed quantity.
Storing of the dispensed quantity setting for subsequent dispensings:
● Press button . The indication of the dispensing time in the digital display stops
blinking.
If the desired dispensed quantity is not achieved:
● With a larger (or smaller) dispensing needle, repeat the steps of Section 5.1.2.1.
Содержание Loctite 135550
Страница 1: ...22121 97102 135550 ...
Страница 2: ...2 ...
Страница 18: ...18 8 Pin Assignment 8 2 XS1 External Start 8 3 XS1 Start via Promixity Switch ...
Страница 20: ...20 9 Declaration of Conformity ...
Страница 21: ...22121 ...
Страница 37: ...37 8 Steckerbelegung 8 2 XS1 Externer Start 8 3 XS1 Start über Näherungsschalter ...
Страница 39: ...39 9 CE Konformitätserklärung ...