6.
Installation
6.1. Function
Please note that the XPM 200HR™ printer is a module designed to be integrated into a
system and to be operated only as a part of that system, for example, in a kiosk. All technical
specifications and instructions contained in this manual and related documentation must be
considered and complied with in order to achieve successful operation in the completed
system.
6.2. Mounting Printer
The XPM 200HR™ printer is designed to be mounted horizontally, (with the paper exit parallel
to the floor), and separately from its controller. See figure 10 and drawing D690075 for
detailed dimensions, mounting screw sizes, etc. If no presenter is being used, the printer may
be angled downward by 90°. It may also be angled upward, as long as the design of the
system into which it mounts is such that a printout cannot slide back into the printer after it is
cut.
Please note that the printer itself mounts via two M4 anchor nuts built into the print
mechanism. An M3 screw with lock washer (not supplied) are used for mounting.
Note: It is critical that the length of the mounting screw conform to the “thread length”
dimensions shown in the drawing below. (Specifically, a minimum of 7.4 mm and a maximum
of 8.5 mm above the mounting surface.) A longer screw may damage the printer, while a
shorter one may not grip it properly.
If a presenter is used, the printer must be mounted parallel to the floor with the paper exiting
to parallel to the floor. An angled orientation will interfere with the loop presenter function.
Care must be taken during installation to ensure that cables are not pinched or cut at any
time, including when any doors or hatches are closed or moving parts of the device moved.