background image

8.

9.

| Original User Manual | Item number 130-300-000 I Subject to change

| Original User Manual | Item number 130-300-000 I Subject to change

EN

EN

Delivery

The filter unit is delivered on a pallet, which can be used for the further transport of the unit. Transport 
must be completed with the help of suitable means of conveyance (forklift, pallet truck, etc.).

When transported further with no or modified original packaging, the system must be perfectly secured 
and protected against damage. The applicable safety regulations must be observed.

Unpacking

1.  Place the pallet on a flat and suitable surface.

2.  Cut the plastic tension straps, e.g. with a pair of scissors.

3.  Remove the protective film.

4.  Lift the appliance off the pallet at the handles with the help of at least another person and set it 

down on the appliance casters.

Regular transport

 

For transport between different setup locations on the same floor of a building, the air purifier is fitted 
with casters that allow the appliance to be rolled without effort. 

1.  Switch the appliance off at the main switch.

2.  Disconnect the power plug and place the cord on top of the appliance.

3.  Release the brakes of the casters and push the appliance to its new place of operation.

4.  Engage the brakes.

Notice:

The appliance must not be exposed to moisture during transport.

Caution:

The plastic tension straps may be under pressure and snap back when they are cut.

Notice:

Transporting the appliance across floors is not recommended due to its weight.

4. Intended use

The air purifier reduces the concentration of germs and viruses, including corona viruses. For this 
purpose, the room air is sucked in through a filter system with the help of a fan and dispersed into the 
room through an outflow opening. The Blue.care

+

 operates with a HEPA H14 filter set that provides for 

effective air purification.

The air purifier is capable of purifying interior rooms (e.g. offices or meeting rooms) by boosting the 
exchange of air per hour by a factor of 4 to 6. The scale found on the appliance refers to a room height of 
2.5 m. For the exact settings to be made at the volume flow regulator, refer to the table:

Level 10 is the level to choose for maximum speed. Please note that the noise of the appliance will 
increase at level 10. 

The system may only be used for this purpose.

Intended use also comprises complying with all instructions provided in the user manual and performing 
the steps necessary for inspection and maintenance as specified.

 

Improper use

Any other use of the appliance exceeding or deviating from the scope of intended use is considered 
improper use and may lead to dangerous situations.

Air exchange  

rate

Room size

4x

5x

6x

according to the scale

30 m²

1

2

3

40 m²

3

5

7

50 m²

5

7

9

Notice:

Operation of the air purifier releases the operator neither from their duty to follow all 
applicable regulatory requirements and to perform general cleaning nor from their 
obligation to preserve the quality of the room air by, for instance, providing for regular 
ventilation and to reduce the risk of direct infection by adhering to sanitary rules such as 
the mandate to wear masks and observe minimum distances. 

Содержание Blue.care plus

Страница 1: ...1 Original User Manual Item number 130 300 000 I Subject to change EN Original User Manual ...

Страница 2: ...d warnings 4 2 Appliance description and scope of supply 6 3 Transport and packaging 7 4 Intended use 9 5 Technical specifications 11 6 Initial operation 12 7 Operation 13 8 Cleaning maintenance and spare parts 14 9 Fault finding and troubleshooting 18 10 Disposal 19 11 Limitation of liability 19 12 EC Declaration of Conformity 20 13 Maintenance table 22 Contents ...

Страница 3: ...e extent of the danger Follow the safety instructions carefully and act with caution to prevent accidents personal industry and damage to property Danger This symbol signifies an immediate risk to the life and the health of persons Failure to observe this information will lead to serious health effects including life threatening injuries Warning This symbol signifies a potential risk to the life a...

Страница 4: ...an outflow opening Scope of supply Please check if the shipment is complete by comparing it to the specified scope of supply Antiviral air purifier with built in HEPA H14 filter set Power cord Key for the maintenance door User guide 3 Transport and packaging Safety instructions Warning There is a risk of injury during transport due to the great weight of the packing unit When loading the packing u...

Страница 5: ... to its weight 4 Intended use The air purifier reduces the concentration of germs and viruses including corona viruses For this purpose the room air is sucked in through a filter system with the help of a fan and dispersed into the room through an outflow opening The Blue care operates with a HEPA H14 filter set that provides for effective air purification The air purifier is capable of purifying ...

Страница 6: ...hnical condition at all times The specified maintenance intervals must be observed The operator must establish a procedure that keeps the appliance or individual parts from being put into operation until all maintenance steps have been completed properly and in a timely manner The operator must keep all safety instructions and warnings attached to the appliance in legible condition and replace the...

Страница 7: ...mes Engage the caster brakes and verify that the appliance is standing firmly Connect the appliance to the power supply system and lay the cord such that no one can trip over it Use the ON OFF switch to turn the appliance on off The ON OFF switch is lit when the appliance is switched on Operation is not permitted unless the filter is installed properly The appliance can only be adjusted to the siz...

Страница 8: ...uctions Exterior cleaning Prior to cleaning the appliance always has to be taken out of service and disconnected by pulling the power plug Use a sufficiently damp cloth and a common cleaning agent for cleaning The work necessary to care for the appliance is largely limited to a regular cleaning of the surfaces No liquids must enter into the electrical parts or through the vent slots Do not use cle...

Страница 9: ...nt towards the maintenance door while the arrows on the filters point in flow control direction 9 Slide in the prefilter all the way and insert it behind the metal rail The main filter must be pushed in all the way above the prefilter 10 Close both locks of the tensioner Verify that the filters are clamped tightly and that the seal of the main filter abuts tightly at the top on the appliance housi...

Страница 10: ...te However please follow all applicable legal provisions and local regulations as well Dispose of the appliance the filter and the packaging materials as prescribed in the applicable legal provisions and local regulations Waste electrical and electronic equipment marked with this symbol must not be disposed of with unsorted domestic waste but needs to be collected separately instead Help protect t...

Страница 11: ...ment and risk reduction ISO 12100 2010 German version EN ISO 12100 2010 DIN EN ISO 14120 2016 05 Safety of machinery Guards General requirements for the design and construction of fixed and movable guards ISO 14120 2015 German version EN ISO 14120 2015 DIN EN ISO 13857 2019 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs ISO 13857 2019 German ver...

Страница 12: ...ber 130 300 000 I Subject to change Original User Manual Item number 130 300 000 I Subject to change EN EN 13 Maintenance table Number Filter change performed on Signature 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ...

Страница 13: ...Hengst SE Nienkamp 55 85 48147 Münster Tel 49 251 20202 0 luftreiniger hengst de www hengst com air purifier ...